Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-04-22
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: According to SOP.
Cross-reference
Reason / purpose for cross-reference:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: SOP_Pulverrinne_vib30_3bar_gs; air
Deviations:
no
Principles of method if other than guideline:
SOP name: Pulverrinne_3bar_vib30_gs
Equipment: Malvern Mastersizer 2000, unit: Scirocco 2000
Dispersing fluid: Air
GLP compliance:
no
Remarks:
According to ECHA Guidance (phys.chem. Studies), GLP compliance is not necessary.
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
2'-chloroacetoacetanilide
EC Number:
202-269-1
EC Name:
2'-chloroacetoacetanilide
Cas Number:
93-70-9
Molecular formula:
C10H10ClNO2
IUPAC Name:
2'-chloroacetoacetanilide
Details on test material:
Date of expiry: Extended to 1.8.2010 (as tested by LC/MS and IR)
Storage: RT
Identity: Confirmed by NMR, IR-and mass spectrometry (LC/MS)
Appearance: White powder
Odour: Non-specific

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Mean:
20.7 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
4.1 µm
St. dev.:
0.2
Percentile:
D50
Mean:
20.7 µm
St. dev.:
2.7
Percentile:
D90
Mean:
72.8 µm
St. dev.:
15.1

Applicant's summary and conclusion

Conclusions:
The median value D50 is = 20.7 µm.
Executive summary:

The study for particle size distribution was performed according to SOP Pulverrinne_3bar_vib30_gs. Method volumetric distribution.

The median value D50 for the particle size distribution of the test item is 20.7 µm, determined with Malvern Mastersizer 2000; unit Scirocco 2000, distribution in air.