Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2001
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study was done following a method in compliance with ISO 17025 but with deviations.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: DIN EN 22719
Deviations:
yes
Remarks:
(Single determination only.)
GLP compliance:
no
Remarks:
ISO 17025 compliance
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
Laurylimidazole
IUPAC Name:
Laurylimidazole
Details on test material:
- Name of test material (as cited in study report): Laurylimidazol

Results and discussion

Flash point
Flash point:
226 °C
Remarks on result:
other: No pressure was reported.

Applicant's summary and conclusion

Conclusions:
Laurylimidazole has a flash point of 226°C.
Executive summary:

The flash point was determined using a Pensky-Martens closed cup flash point apparatus. Few details were provided, but the DIN EN 22719 method was followed. The laboratory didn’t have enough test material for a duplicate test. The use of Pensky-Martens apparatus is approved for this endpoint per EC no. 92/69/EEC, Part A.9: "Flash-Point". Therefore this study is classified as reliable with restrictions.