EC number: 477-320-6 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Emergency measure - Inhalation: Remove to fresh air. Get medical attention.
Emergency measure - Eyes: Flush with water for 15 minutes. Get medical attention.
Emergency measure - Skin: Flush with water for 15 minutes. Remove contaminated
clothing. Get medical attention.
Emergency measure - Ingestion: If victim is conscious give 2-4 glasses of milk or water.
Immediately get medical attention.
Fire-fighting measures
Recommended extinguishing agent: Dry chemical, foam, carbon dioxide.
Product arising from burning: Oxides of carbon, hydrofluoric acid, peroxides.
Product determined by test: N
Protective equipment: Firefighters should wear full protective clothing including
self contained breathing apparatus. Firefighters should
avoid inhaling any combustion products.
Accidental release measures
Emergency measures in case of spillage: Contain the discharged material. Do not allow the spilled
product to enter public drainage system or open water
courses. Dike the spilled material, where this is possible.
Handling and storage
Handling: Wear personal protective equipment to avoid exposure.
Negative pressure respirator with organic vapor cartridge is
required if vapor concentration exceeds limits specified
inappropriate jurisdictional directives.
Use in well-ventilated area. Lab hood or point source
ventilation recommended.
Storage: Store in a cool and dry location. May be stored in glass or
polyethylene containers.
Packaging of the substance and or preparation: Polyethylene 20 litre pails, polyethylene 120 litres
drums.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Transport code: Substance and preparation are not hazardous by IATA, etc.
Transport: No special transport required.
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Stability and reactivity
Danger other than fire: None reported.
Chemical reaction with water: Will not react with water.
Dust explosion: Product is a liquid at room temperature.
Dust explosion determined by test: N
Disposal considerations
Industry - Possibility of recovery/recycling: Uncontaminated substance can be recovered and used as
normal.
Recovery by mechanical collection.
Industry - Possibility of neutralisation: Not applicable.
Industry - Possibility of destruction: controlled discharge: Not applicable.
Industry - Possibility of destruction - incineration: Substance can be destroyed by incineration at temperatures
greater than 2,000ºC
Incinerate, high temperature -long burn with gas
scrubbing.
Incinerate in halogen specific incinerators.
Industry - Possibility of destruction - water purification: Not applicable.
Public at large - Possibility of recovery/recycling: Public at large will not be handling substance or
preparation of substance. Substance in paint, varnish, etc.
will be at very low concentrations, i.e. 100 to 300 ppm and
as such constitutes no hazard.
Public at large - Possibility of neutralisation: Not applicable.
Public at large - Possibility of destruction: controlled discharge: Not applicable.
Public at large - Possibility of destruction - incineration: Not applicable.
Public at large - Possibility of destruction - water purification: Not applicable.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.