Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove patient to fresh air. Symptomatic treatment.
Emergency measure - Eyes: Rinse with water for at least 15 minutes. Seek medical
attention.
Emergency measure - Skin: Wash with soap and water. If symptoms develop, obtain
medical attention.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water spray, foam, dry powder or carbon dioxide may be used.

Product arising from burning: Products of combustion may contain oxides of carbon,
nitrogen and sulfur, hydrogen fluoride gas and some soot.

Product determined by test: N

Protective equipment: A self contained breathing apparatus and suitable protective
clothing should be worn.

Accidental release measures

Emergency measures in case of spillage: Wear suitable protective clothing, see 2.3.1 and ventilate
area. Avoid static discharges and extinguish naked flames.
Clean up spill using mechanical methods and avoid dust
formation. Transfer to suitable labelled containers and
dispose of in accordance with local regulations.

Handling and storage

Handling: Ensure adequate ventilation and do not breathe dust. Gloves
and safety goggles should be worn. Avoid contact with skin
and eyes and wash hands after handling.

Storage: Store in tightly closed containers in cool, dry and well
ventilated conditions.

Packaging of the substance and or preparation: The substance is packaged in double lined polyethylene bags
packed in twos in Bowater containers.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is not possible.

Industry - Possibility of neutralisation: None reported.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: Incinerate at a suitable facility. Waste gas treatment to
remove oxides of nitrogen and sulfur should be fitted
(A661)

Industry - Possibility of destruction - water purification: Not recommended, the substance should not be discharged to
watercourses.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.