Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 422-460-5 | CAS number: 137234-87-8 UK-103,442
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
Emergency measure - Inhalation: Remove patient to fresh air. Seek medical attention immediately.
Emergency measure - Eyes: Irrigate for at least 15 minutes and seek medical attention.
Emergency measure - Skin: Remove contaminated clothing Wash with water. If irritation develops seek medical attention.
Emergency measure - Ingestion: Never give anything by mouth to an unconscious person. Wash out mouth with water. Do not induce vomiting unless directed by medical personnel. Seek medical attention immediately.
Fire-fighting measures
Recommended extinguishing agent: Water spray, foam, dry powder or carbon dioxide may be used.
Product arising from burning: Products of combustion may contain oxides of carbon and nitrogen and hydrogen fluoride.
Fire / Explosion Hazards: Strong dust explosion characteristic.
Advice for Fire-Fighters: During all fire fighting activities, wear appropriate protective equipment, including self-contained breathing apparatus.
Protective equipment: A self-contained breathing apparatus should be worn.
Accidental release measures
Personal Precautions, Protective Equipment and Emergency Procedures: Personnel involved in clean-up should wear appropriate personal protective equipment. Minimize exposure. Eliminate all sources of ignition and ventilate area using explosion-proof equipment.
Environmental Precautions: Place waste in an appropriately labeled, sealed container for disposal. Care should be taken to avoid environmental release.
Methods and Material for Containment and Cleaning Up
Contain the source of the spill if it is safe to do so. Collect spilled material by a method that controls dust generation. Clean spill area thoroughly. Avoid use of a filtered vacuum to clean spills of dry solids, due to the potential for electrostatic discharge and the strong dust explosion characteristic.
Additional Consideration for Large Spills:
Non-essential personnel should be evacuated from affected area. Report emergency situations immediately. Clean up operations should only be undertaken by trained personnel
Handling and storage
Ground and bond all bulk transfer equipment. Avoid open handling. Minimize dust generation. Use local exhaust ventilation orperform work under fume hood/fume cupboard. Avoid inhalation and contact with skin, eye, and clothing. When handling, use appropriate personal protective equipment. Wash hands and any exposed skin after removal of PPE. All conductive elements of the system that contact the dry substance should be properly bonded and grounded and equipped with proper explosion relief or suppression systems. This material should not be flowed through nonconductive ducts or pipes
because of the potential for electrostatic discharge ignition. Restricting the use of high resistivity materials, such as plastics, should be considered. Releases to the environment should be avoided. Review and implement appropriate technical and procedural waste water and waste disposal measures to prevent occupational exposure or environmental releases. Potential points of process emissions of this material to the atmosphere should be controlled with dust collectors, HEPA filtration systems or other equivalent controls.
Conditions for Safe Storage, Including any Incompatibilities
Storage Conditions: Store at room temperature in properly labeled containers. Keep away from heat, sparks and flame
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- UN 3077
Shipping information
- Proper shipping name and description:
- UN proper shipping name: Environmentally Hazardous Substance, Solid, n.o.s (Substituted pyrimidine), Marine Pollutant
- Language:
- English
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- UN 3077
Shipping information
- Proper shipping name and description:
- UN proper shipping name: Environmentally Hazardous Substance, Solid, n.o.s (Substituted pyrimidine), Marine Pollutant
- Language:
- English
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- UN 3077
Shipping information
- Proper shipping name and description:
- UN proper shipping name: Environmentally Hazardous Substance, Solid, n.o.s (Substituted pyrimidine), Marine Pollutant
- Marine pollutant
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- UN 3077
Shipping information
- Proper shipping name and description:
- UN proper shipping name: Environmentally Hazardous Substance, Solid, n.o.s (Substituted pyrimidine), Marine Pollutant
Remarksopen allclose all
Additional transport information
Additional information
- Special provisions / remarks / other:
- Transport code: UN 3077, Class 9
Transport: Environmentally hazardous substance, Solid, NOS (Pharmaceutical Intermediate).
Keep containers tightly sealed and store upright during storage. If possible, secure to prevent containers from falling over.
Exposure controls / personal protection
Engineering Controls: Engineering controls should be used as the primary means to control exposures. Use process containment, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits.
Personal Protective Equipment:
Refer to applicable national standards and regulations in the selection and use of personal protective equipment (PPE).
Hands: Wear impervious gloves as minimum protection.
Eyes: Wear safety glasses as minimum protection.
Skin: Wear impervious protective clothing when handling this compound.
Respiratory protection: If the applicable Occupational Exposure Limit (OEL) is exceeded, wear an appropriate respirator with a protection factor sufficient to control exposures to below the OEL.
Stability and reactivity
Danger other than fire: None reported. Chemical reaction with water: None reported.
Dust Explosivity:
Max. Explosion Pressure (bar): 9.0
Max. Rate of Pressure Rise (bar/sec): 768
Kst Value (bar*m/s): 208
St Class: 2
Min. Ignition Energy (mJ): 35-40
Min. Ignition Temperature (°C): 530
Limiting Oxygen Concentration (% vol): 13
Min. Explosion Concentration (g/m3): 45 g/m³
Electrostatic Risk:
Charge Relaxation Time:
Ambient Humidity: <1 Hours
Low Humidity: Hours
Resistivity (ohm-m):
Powder: Ambient: 1.1E+7
Low: 1.1E+11
Polymerization: Will not occur
Disposal considerations
Waste Treatment Methods: Dispose of waste in accordance with all applicable laws and regulations. Member State specific and Community specific provisions must be considered. Considering the relevant known environmental and human health hazards of the material, review and implement appropriate technical and procedural waste water and waste disposal measures to prevent occupational exposure and environmental release. It is recommended that waste minimization be practiced. The best available technology should be utilized to prevent environmental releases. This may include destructive techniques for waste and wastewater.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.