Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 July 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Lot No.of test material: 624730
- Physical state: clear and viscous liquid with a faint yellow coloring
- Expiration date of the lot/batch: Dec 2017
- Purity: 97.1%

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: room temperature
Key result
Flash point:
150.5 °C
Atm. press.:
101.3 kPa

The study result of 150.0 °C was corrected to 150.3 °C to account for standard barometric pressure and then rounded to 150.5 °C.

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of MTDID 47403 was 150.5 °C under atmospheric conditions (101.3 kPa) according to EU Method A.9.
Executive summary:

The flash point of MTDID 47403 was tested using a closed-cup method. The flash point was determined in three runs. The test material ignited at 150 °C but did not ignite at 149.0 °C at 100.1 kPa. The lowest flash point corrected to 101.3 kPa was rounded to the nearest 0.5 °C, and was determined to be 150.5 °C. The study was conducted in accordance with EU Method A.9 and under GLP; therefore the study is considered reliable without restriction.

Endpoint:
flash point of flammable liquids
Type of information:
not specified
Adequacy of study:
supporting study
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
documentation insufficient for assessment
Qualifier:
no guideline followed
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
> 100 °C
Conclusions:
A flash point of > 100 °C using the closed cup method was reported for MTDID 47403.
Executive summary:

A flash point of > 100 °C using the closed cup method was reported for MTDID 47403. Only the result was reported on the SDS and no further information about procedure or test conditions were provided; therefore, the reliability of the data is not assignable.

Description of key information

The flash point of MTDID 47403 was 150.5 °C under atmospheric conditions (101.3 kPa) according to EU Method A.9.

Key value for chemical safety assessment

Additional information

In the key study, the flash point of MTDID 47403 was tested using a closed-cup method. The flash point was determined in three runs. The lowest flash point corrected to 101.3 kPa was rounded to the nearest 0.5 °C, and was determined to be 150.5 °C. The study was conducted in accordance with EU Method A.9 and under GLP; therefore the study is considered reliable without restriction. In a supporting study, a flash point of > 100 °C using the closed cup method was reported for MTDID 47403. Only the result was reported on the SDS and no further information about procedure or test conditions were provided; therefore, the reliability of the data is not assignable.