Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
03 March 2004 to 09 March 2004
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study performed in accordance with EU and ISO test guidelines in compliance with GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
not specified
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
236.5 °C
Atm. press.:
102.6 kPa

Preliminary test

Estimated flash-points for test substance

Test substance

Estimated flash-point [°C]

Hatcol 2352

235

 

Main study

Summary of the measured flash-points and the lowest flash-point.

Test

Flash-point [°C]

Lowest flash-point [°C]

1

237

237

2

239

 

The lowest flash-point was corrected for the atmospheric pressure (i.e. 102.6 kPa).

Corrected flash-point = 237÷0.25(101.3-102.6)°C= 236.68°C

Rounded off to 0.5°C gives the flash-point for Hatcol 2352: 236.5°C.

Conclusions:
Rounded off to 0.5°C gives the flash-point for Hatcol 2352: 236.5°C.
Executive summary:

The determination of the flash-point was performed in accordance with EEC-Directive 92/69 EEC, A.9 "Flash-point" (1992) and DIN EN 22719: "Bestimmung des Flammpunktes Verfhrennach Pensky Martens im geschlossenen Tiegel"; December 1993.

 

The flash-point determined for Hatcol 2352, using the Pensky-Martens closed cup flash-point apparatus is 236.5°C.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 October 2002
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study performed in accordance with EU test guidelines in compliance with GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
not specified
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
215.5 °C
Atm. press.:
100.1 kPa
Remarks on result:
other: Flash-point corrected for the atmospheric pressure

Preliminary test

Flash-point: 225°C

 

Main study

Table 1: Determined flash-points during the main study

Test number

Flash-point [°C]

Lowest Flash-point [°C]

1

215

215

2

215

 

The atmospheric pressure on the day of the test, was 100.10 kPa.

The lowest flash-point was corrected for the atmospheric pressure.

Corrected flash-point   = 215 + 0.25 (101.3-100.10)°C

= 215.30°C

Conclusions:
The flash-point of Hatcol 3331 is 215.5°C under the conditions of the test.
Executive summary:

The determination of the flash-point of Hatcol 3331 was performed using a Pensky-Martens closed cup flash-point apparatus, in accordance with EEC-Directive 92/69 EEC, A.9 "Flashpoint" (1992) and DIN EN 22719: "Bestimmung des Flammpunktes Verfahren nach Pensky-Martens imgeschlossenen Tiegel"; December 1993.

The flash-point of Hatcol 3331 is 215.5°C when using a Pensky-Martens closed cup flash-point apparatus.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 October 2002
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study performed in accordance with EU test guidelines in compliance with GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
not specified
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
129 °C
Atm. press.:
101.76 kPa

Determined flash-points during the main study

Test number

Flash-point [°C]

1

198

2

195

 

Conclusions:
The flash point of Hatcol 3344 is 129°C.
Executive summary:

The determination of the flash-point of Hatcol 3344 was performed using a Pensky-Martens closed cup flash-point apparatus, in accordance with EEC-Directive 92/69 EEC, A.9 "Flashpoint" (1992) and DIN EN 22719: "Besummung des Flammpunktes Verfahren nach Pensky-Martens im geschlossenen Tiegel"; December 1993.

The flash-point of Halcol 3344, determined during the preliminary test is 129°C.

During the main study, the flash-point of Hatcol3344 is determined to be 198°C and 195°C in test 1 and 2, respectively.

For safety reasons, the lowest temperature at which the test substance vapour / air mixture could be ignited (determined during the preliminary test) will be taken as the flash-point of Hatcol 3344.

In conclusion, the flash-point of Hatcol 3344 is 129°C under the conditions of the test.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 October 2002
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study performed in accordance with EU test guidelines in compliance with GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
not specified
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
120.5 °C
Atm. press.:
100.1 kPa

Determined flash-points during the main study

Test number

Flash-point [°C]

Lowest Flash-point [°C]

1

120

120

2

124

Conclusions:
The flash-point of Hatcol 5236 is 120.5°C under the conditions of the test.
Executive summary:

The determination of the flash-point of Hatcol 5236 was performed using a Pensky-Martensclosed cup flash-point apparatus, in accordance with EEC-Directive 92/69 EEC, A.9 "Flashpoint' (1992) and DIN EN 22719: "Beslimmung des Flammpunktes Verfhren nach Pensky-Martens im geslossenen liegel"; December 1993.

The flash-point of Hatcol 5236 is 120.5°C when using a Pensky-Martens closed cup flash-point apparatus.

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
26 september 2006
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: non-GLP test
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D-92
GLP compliance:
no
Type of method:
equilibrium method closed cup
Key result
Flash point:
249 °C
Atm. press.:
100.21 kPa
Remarks on result:
other: corrected flash point
Conclusions:
The flash point of the test item has been determined to be 249°C using a closed cup equilibrium method (Pensky-Martin Closed Cup apparatus) .
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Basic data given. Certificate of Analysis.
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup
Remarks:
ASTM D93 / IP 34 / EN22719
Key result
Flash point:
262.5 - 264.5 °C
Atm. press.:
1 013 hPa

Description of key information

The determination of the flash-point was performed in accordance with EEC-Directive 92/69 EEC, A.9 "Flash-point" (1992).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
236.5 °C

Additional information

HATCOL 2352

The flash-point determined for Hatcol 2352, using the Pensky-Martens closed cup flash-point apparatus is 236.5°C.

 

HATCOL 3331

The flash-point of Hatcol 3331 is 215.5°C when using a Pensky-Martens closed cup flash-point apparatus.

 

HATCOL 3344

The flash-point of Hatcol 3344, determined during the preliminary test is 129°C.

During the main study, the flash-point of Hatcol 3344 is determined to be 198°C and 195°C in test 1 and 2, respectively.

For safety reasons, the lowest temperature at which the test substance vapour / air mixture could be ignited (determined during the preliminary test) will be taken as the flash-point of Hatcol 3344.

In conclusion, the flash-point of Hatcol 3344 is 129°C under the conditions of the test.

 

HATCOL 5236

The flash-point of Hatcol 5236 is 120.5°C when using a Pensky-Martens closed cup flash-point apparatus.

HATCOL 1510

The flash point of substance EC # 268-596-7 was determined to be 249 °C using the equilibrium method (Pensky-Martens closed cup).

HATCOL 1765

The flash point of the substance pentaerythritol tetraesters of n-decanoic, n-heptanoic, n-octanoic and n-valeric acids (CAS 68424 -31 -7) was deduced from a similar substance with a very similar specification using the ISO 2719:2002 Pensky-Martens closed cup method.