Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
self-heating substances / mixtures
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05 Dec 2017 - 09 Jan 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.4 (Test method for self-heating substances)
Version / remarks:
Rev. 6 (2015)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
(2S)-5-methoxy-N-propyl-1,2,3,4-tetrahydronaphthalen-2-aminium (2R)-(2-chlorophenyl)(hydroxy)acetate
EC Number:
814-350-4
Cas Number:
1352917-66-8
Molecular formula:
C22 H28 N Cl O4
IUPAC Name:
(2S)-5-methoxy-N-propyl-1,2,3,4-tetrahydronaphthalen-2-aminium (2R)-(2-chlorophenyl)(hydroxy)acetate
Test material form:
solid: particulate/powder
Details on test material:
- Appearance: White powder
- Storage condition of test material: At room temperature

Results and discussion

Self-heating substances / mixtures
Key result
Test procedure:
100 mm sample cube at 140°C
Result:
negative outcome (no effect observed)

Any other information on results incl. tables

No spontaneous ignition occurred and no exothermic effect of the test item was observed. After the experiment, the test item had turned into a brown molten residue and was collected in a container that was placed below the cube. It indicated that the test item had been molten, decomposed and/or reacted during the experiment.

 

Applicant's summary and conclusion

Interpretation of results:
other: not classified based on GHS or CLP criteria
Conclusions:
The substance is not self-heating.