EC number: 265-967-5 | CAS number: 65894-76-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Water solubility
Administrative data
Link to relevant study record(s)
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 28 July 2017 to 05 October 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Version / remarks:
- 1995
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.6 (Water Solubility)
- Version / remarks:
- 2008
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- flask method
- Key result
- Water solubility:
- 0.128 g/L
- Conc. based on:
- test mat.
- Incubation duration:
- 24 h
- Temp.:
- 20 °C
- pH:
- 3.4
- Details on results:
- PRELIMINARY TEST
- The preliminary estimate of water solubility was 0.137 g/L at 20 °C.
MAIN TEST
- The mean areas relating to the main test material peak of the standard, sample and blank solutions are shown in Tables 1 and 2.
- The concentration (g/L) of test material in the sample solutions is shown in Tables 3 and 4.
- Overall result samples 1 to 3: The concentration of test material decreased when increasing the shaking period, possibly due to test material degradation.
- Overall result samples 4 to 7: Samples appeared to have reached saturation after 3 hours of shaking.
VALIDATION
- The linearity of the detector response with respect to concentration was assessed over the nominal concentration range of 1.00 to 100 mg/L in 75:25 v/v acetonitrile:water. The results were satisfactory with a goodness of fit coefficient (r^2) of 1.000 being obtained.
DISCUSSION
- On removal of the samples from the static 20 °C water bath, all seven sample solutions were observed to be clear and colourless with excess, undissolved test material present. Aliquots of the solutions were centrifuged and then sampled using a syringe and needle. Each supernatant was then observed to be clear, colourless and free from undissolved test material.
- The chromatography obtained for the first three samples (1 to 3), suggested hydrolysis of the test material. The main test material peak at approximately 3.3 min decreased with shaking time, while the peaks at approximately 1.5 and 1.9 min increased. Therefore, the first two peaks in the chromatography were attributed to degradation products. The area of the peak at approximately 5.0 min did not change significantly and was attributed to an impurity.
- Four extra samples (4 to 7) were prepared using reduced shaking and equilibration times, in an attempt to minimise test material hydrolysis. The sample and standard analysis matrices were also acidified to this effect (peak at approximately 1.3 min in the chromatography corresponds to phosphoric acid). The results indicate that the sample solutions reached saturation after 3 hours of shaking; hence, the concentrations determined for samples 6 and 7 have been used to generate the final water solubility result. - Conclusions:
- Under the conditions of this study, the water solubility of the test material has been determined to be 0.128 g/L of solution at 20.0 ± 0.5 °C.
- Executive summary:
The water solubility of the test material was determined in accordance with the standardised guidelines OECD 105 and EU Method A.6, under GLP conditions.
The test was performed using the flask method and samples were analysed using HPLC. The preliminary estimate of water solubility was 0.137 g/L at 20 °C.
On removal of the samples from the static 20 °C water bath, all seven sample solutions were observed to be clear and colourless with excess, undissolved test material present. Aliquots of the solutions were centrifuged and then sampled using a syringe and needle. Each supernatant was then observed to be clear, colourless and free from undissolved test material.
The chromatography obtained for the first three samples (1 to 3), suggested hydrolysis of the test material. The main test material peak at approximately 3.3 min decreased with shaking time, while the peaks at approximately 1.5 and 1.9 min increased. Therefore, the first two peaks in the chromatography were attributed to degradation products. The area of the peak at approximately 5.0 min did not change significantly and was attributed to an impurity. Four extra samples (4 to 7) were prepared using reduced shaking and equilibration times, in an attempt to minimise test material hydrolysis. The sample and standard analysis matrices were also acidified to this effect (peak at approximately 1.3 min in the chromatography corresponds to phosphoric acid). The results indicate that the sample solutions reached saturation after 3 hours of shaking; hence, the concentrations determined for samples 6 and 7 have been used to generate the final water solubility result.
Under the conditions of this study, the water solubility of the test material has been determined to be 0.128 g/L of solution at 20.0 ± 0.5 °C.
Reference
Table 1: The mean areas relating to the main test material peak of the standard, sample and blank solutions in samples 1 to 3
Solution |
Mean PeakArea |
Matrix Blank |
None detected |
Standard Solution 37.7 mg/L |
1.3591 x 10^7 |
Standard Solution 37.7 mg/L |
1.3469 x 10^7 |
Sample 1, Replicate Dilution A |
8.6634 x 10^6 |
Sample 1, Replicate Dilution B |
8.7186 x 10^6 |
Sample 2, Replicate Dilution A |
7.3517 x 10^6 |
Sample 2, Replicate Dilution B |
7.4554 x 10^6 |
Sample 3, Replicate Dilution A |
2.7741 x 10^6 |
Sample 3, Replicate Dilution B |
2.7271 x 10^6 |
Table 2: The mean areas relating to the main test material peak of the standard, sample and blank solutions in samples 4 to 7
Solution |
Mean Peak Area |
Standard Matrix Blank |
None detected |
Standard Solution 37.7 mg/L |
1.4356 x 10^7 |
Standard Solution 37.7 mg/L |
1.4351 x 10^7 |
Sample 4, Replicate Dilution A |
1.1329 x 10^7 |
Sample 4, Replicate Dilution B |
1.1239 x 10^7 |
Sample 5, Replicate Dilution A |
1.1741 x 10^7 |
Sample 5, Replicate Dilution B |
1.1749 x 10^7 |
Sample 6, Replicate Dilution A |
1.2142 x 10^7 |
Sample 6, Replicate Dilution B |
1.2235 x 10^7 |
Sample 7, Replicate Dilution A |
1.2173 x 10^7 |
Sample 7, Replicate Dilution B |
1.2234 x 10^7 |
Sample Matrix Blank |
None detected |
Table 3: The concentration (g/L) of test material in the sample solutions 1 to 3
Sample Number |
Time Shaken |
Time Equilibrated at 20 ºC (h) |
Concentration (g/L) |
Solution pH |
1 |
24 |
24 |
9.68 x 10-2 |
3.37 |
2 |
48 |
24 |
8.25 x 10-2 |
3.28 |
3 |
72 |
24 |
3.07 x 10-2 |
3.27 |
Table 4: The concentration (g/L) of test material in the sample solutions 4 to 7
Sample Number |
Time Shaken |
Time Equilibrated at 20 ºC (h) |
Concentration (g/L) |
Solution pH |
4 |
1 |
1 |
0.119 |
4.11 |
5 |
2 |
1 |
0.123 |
3.78 |
6 |
3 |
1 |
0.128 |
3.73 |
7 |
24 |
1 |
0.128 |
3.40 |
Description of key information
Under the conditions of this study, the water solubility of the test material has been determined to be 0.128 g/L of solution at 20.0 ± 0.5 °C.
Key value for chemical safety assessment
- Water solubility:
- 0.128 g/L
- at the temperature of:
- 20 °C
Additional information
The water solubility of the test material was determined in accordance with the standardised guidelines OECD 105 and EU Method A.6, under GLP conditions. The study was awarded a reliability score of 1 in accordance with the criteria set forth by Klimisch et al. (1997).
The test was performed using the flask method and samples were analysed using HPLC. The preliminary estimate of water solubility was 0.137 g/L at 20 °C.
On removal of the samples from the static 20 °C water bath, all seven sample solutions were observed to be clear and colorless with excess, undissolved test material present. Aliquots of the solutions were centrifuged and then sampled using a syringe and needle. Each supernatant was then observed to be clear, colourless and free from undissolved test material.
The chromatography obtained for the first three samples (1 to 3), suggested hydrolysis of the test material. The main test material peak at approximately 3.3 min decreased with shaking time, while the peaks at approximately 1.5 and 1.9 min increased. Therefore, the first two peaks in the chromatography were attributed to degradation products. The area of the peak at approximately 5.0 min did not change significantly and was attributed to an impurity.Four extra samples (4 to 7) were prepared using reduced shaking and equilibration times, in an attempt to minimise test material hydrolysis. The sample and standard analysis matrices were also acidified to this effect (peak at approximately 1.3 min in the chromatography corresponds to phosphoric acid). The results indicate that the sample solutions reached saturation after 3 hours of shaking; hence, the concentrations determined for samples 6 and 7 have been used to generate the final water solubility result.
Under the conditions of this study, the water solubility of the test material has been determined to be 0.128 g/L of solution at 20.0 ± 0.5 °C.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.