Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 214-874-8 | CAS number: 1204-28-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Oxidising properties
Administrative data
Link to relevant study record(s)
- Endpoint:
- oxidising solids
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the organic substance contains oxygen or halogen atoms which are chemically bonded only to carbon or hydrogen and hence, the classification procedure does not need to be applied
- Justification for type of information:
- JUSTIFICATION FOR DATA WAIVING
An expert statement has been written, based on CLP/UN screening procedure criteria.
The test item does not contain chemical groups that act as oxidizing agents. Furthermore, oxygen and halogen atoms present in the molecular structure are chemically bonded to carbon or hydrogen. The molecular structures of impurities at ≤ 1% were not taken into account.
In conclusion, the substance is considered to have NO oxidising properties. - Reason / purpose for cross-reference:
- data waiving: supporting information
- Endpoint:
- oxidising solids
- Type of information:
- other: Statement based on the structure of the test item according to international guidelines.
- Adequacy of study:
- supporting study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Qualifier:
- according to guideline
- Guideline:
- other: United Nations (UN), UN no. ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Appendix 6: “Screening Procedures”
- Version / remarks:
- 2009
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- UN Manual of Tests and Criteria: Test O.1 (Test for oxidizing solids)
- Version / remarks:
- 2009
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.17 (Oxidising Properties (Solids))
- Version / remarks:
- Regulation EC no. 440/2008
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- 4-chloroformylphthalic anhydride
A statement was made regarding the oxidizing properties of the test item. - Parameter:
- preliminary test
- Remarks on result:
- not measured/tested
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- The test item is considered to possess NO oxidizing properties.
- Executive summary:
A statement was made to conclude on the oxidising properties on the test item.
This statement has been done according to recognized guidelines (UN O1 and Appendix 6: “Screening Procedures”; EU A.17) and under GLP. No deviation from the guidelines was recorded.
Based on the composition and the molecular structure of the test item, it is considered to possess NO oxidizing properties.
Referenceopen allclose all
The test item is typically very pure. None of the components does contain groups that act as an oxidizing agent. The oxygen and halogen atoms that are present in the molecular structure of the test item are chemically bonded to carbon or hydrogen.
Description of key information
Testing for oxidising properties not required.
Key value for chemical safety assessment
- Oxidising properties:
- non oxidising
Additional information
A statement was made to conclude on the oxidising properties on the test item.
This statement has been done according to recognized guidelines (UN O1 and Appendix 6: “Screening Procedures”; EU A.17) and under GLP. No deviation from the guidelines was recorded.
Justification for classification or non-classification
Based on the composition and the molecular structure of the test item, it is considered to possess NO oxidizing properties.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.