Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 212-782-2 | CAS number: 868-77-9
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Exposure related observations in humans: other data
Administrative data
- Endpoint:
- exposure-related observations in humans: other data
- Remarks:
- potential occupational asthma cases
- Type of information:
- other: case study compilation
- Adequacy of study:
- weight of evidence
- Reliability:
- 4 (not assignable)
- Rationale for reliability incl. deficiencies:
- documentation insufficient for assessment
- Remarks:
- Significant confounding factors were coexposure to other volatiles and various dusts; unclear inhalative exposure to HEMA and the pre-occupational clinical status of the majority of patients
Data source
Reference
- Reference Type:
- publication
- Title:
- Occupational respiratory hypersensitivity caused by preparations containing acrylates in dental personnel
- Author:
- Piirilä P, Kanerva H, Keskinen H, Estander T, Hytönen M, Tuppurainen M, Nordman H
- Year:
- 1 998
- Bibliographic source:
- Clin. Exp. Allergy 28, 1404-1411
Materials and methods
- Type of study / information:
- Case study compilation
- Endpoint addressed:
- respiratory sensitisation
Test material
- Reference substance name:
- 2-hydroxyethyl methacrylate
- EC Number:
- 212-782-2
- EC Name:
- 2-hydroxyethyl methacrylate
- Cas Number:
- 868-77-9
- Molecular formula:
- C6H10O3
- IUPAC Name:
- 2-hydroxyethyl methacrylate
Constituent 1
Method
- Ethical approval:
- not specified
- Details on study design:
- According to the authors: "Flow-volume spirometry was performed with a rolling seal spirometer (Mijnhardt, Vicalest 3) connected to a microcomputer (Medicro MR-3), and Viljanen's reference values were used. Histamine challenge tests were performed according Sovijarvi's method following FEV1 (Forced
expiratory volume in one second) values with a Vitalograph S bellow spirometer (Viralograph, Buckingham, UK). A 15% reduction in FEV 1 was considered significant and the provocative dose of histamine diphosphate causing a 15% reduction in FEY1 (PD15) was measured. The hyperresponsiveness was graded as strong with PD15 <0.10mg, moderate with 0.11-0.40mg and slight with 0.41 -1.6 mg.
The long-term peak expiratory flow (PEF) monitoring at the workplace and on days off was made
according to the method of Burge and the occupational effect was evaluated visually from the plotted presentation.
Sin prick test to common environmental allergens were performed using a previously described method. All patients were also tested with natural rubber latex gloves, and a commercial latex extract {Stallergenes S.A., Fresnes Cedex. France); tests with chloramine T were done if there was a positive work history also. Skin prick tests with methyl methacrylatc (MMA), 2-hydroxymethyl
methacrylate (2-HEMA), bisfenol-A-diglycidylether-mcthacrylate (BIS-GMA}, ethyleneglycol dimethacrylate (EGDMA) and triethyleneglycol dimethacrylate (TREGDMA) were done with human serum albumin (HSA) conjugates as previously described.
The skin patch tests to acrylates were done with the occlusive Finn Chamber(R) technique.
Inhalation challenge tests with a placebo and dental acrylate compounds {mixtures in liquid or powder form) were performed in a 6 m3 challenge chamber according to the international guidelines. If the acrylate compound was in liquid form, the patient handled the compound
for 30 min as follows: six drops of the dental primer and 6 drops of the dental adhesive were added simultaneously for 10 min; two drops of each were then added in turn for 5 min and repeated once. If the challenge test was negative, the challenge test was repeated on another day with a double dose of both substances. The control challenge test was done with polyol (Hydrogenated decene oligorners, Nexbase 200 6FG, Neste PAO NV, Beringen, Belgium} if the agent tested was in fluid form and with lactose if it was in powder form.
The FEV1 and PEF values during the challenge test procedure were measured by a portable pocket-size spirometer {Micro Plus Spirometer, Micro Medical, UK). In case of patients 1 and 2. the PEF values were followed up with a Wright peak flow meter (Clement Clarke M286, Ferraris
Medical) and the FEV I values with a Vitalograph S bellow spirometer (Yitalograph, Buckingham, UK) according to a method reported earlier. The clinical symptoms and lung auscultation were recorded as well.
The mucosal response of the nose during the challenge tests was registered and nasal blockage and rhinorrhoea were scored before and after the provocation test according to a method by Hytonen and Sala. Physiological measurements were also used in the recording of the change in the nasal blockage either by rhinomanometry (Rhinomanometer NRG. Mercury Electronics, Glasgow, UK) or acoustic rhinometry (RHIN2000, SR Electronics APS, Lynge, Denmark). The nasal response was considered positive if the status change and physiological measurement criteria were fulfilled. A scoring method was used in che evaluation of the laryngeal and pharyngeal response. The ocular reaction was followed and evaluated by an ophthalmologist as described
earlier. - Exposure assessment:
- not specified
- Remarks:
- Inhalative exposure to HEMA or any other substance was not determined, neither in the occupational setting nor in the challenge test, and just assumed based on the use of the mixed dental products.
Results and discussion
- Results:
- see overall remarks
Applicant's summary and conclusion
- Conclusions:
- The reported clinical cases suffer from a consistent picture in terms of medical diagnosis that would allow to conclude on a typical mode of action for these substances (e.g. heterogeneous IgE and SIC pattern). On substance level, the specificity is rated low as only mixed exposure was investigated, in the occupational setting as well as in the SIC tests. Given the low vapour pressure of the substances, and as consequence the partially unknown respiratory exposure in general, a low biological plausibility is assigned. Overall, a low level of confidence and a high level of uncertainty is considered for these cases to provide evidence that HEMA is a respiratory sensitiser.
- Executive summary:
Seven cases, thereof 5 dental nurses and 2 dentists, were identified from the dental sector. In 6 of those, OA was diagnosed, in the 7th case rhinitis. Based on the case descriptions, occupational exposure to HEMA is considered as likely, but not to HPMA. There is relevant co-exposure to other substances that are contained in dental products used as primer and adhesives, predominantly bis-GMA but also inorganic material like quartz, Alumina or silica. With exception of case #7, all patients had a clinical history that indicate immunologic hypersensitivity (atopy – individual or in the family) or respiratory hypersensitivity (unspecific bronchial hyperreactivity). The IgE responses (unspecific indicator for immune-based mechanisms; only tested with the Piirilä patients), were heterogenous with four cases without increase and 3 with increase. SIC tests were performed in 7 cases with the HEMA containing dental primers and/ or adhesives and thus with mixtures, by repeating typical dental handling routines during the SIC. Like the IgE responses, the SIC responses were heterogeneous, with 3 LAR, 3 EAR and one negative test. Regarding the ECHA R.7a requirements, the majority of information was not available to assess the cases.
The cases were assessed in a formal WoE assessment on the respiratory sensitisation potential of HEMA and HPMA as attached to the dossier; the summary of this assessment is available in the endpoint summary of the chapter "Sensitisation".
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.