First-aid measures

- After eye contact : P305+351+338 Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do.

                                   Continue rinsing.

                                    P313 Get medical advice/attention.

- After skin contact : P302+352 Wash with plenty of water.

- After inhalation : P304+340 Remove person to fresh air and keep comfortable for breathing.

- After swallowing : P314 Get medical advice/attention if you feel unwell.

Fire-fighting measures

- Suitable extinguishing media : Dry chemical, foam chemical, carbon dioxide, sand

- Unsuitable extinguishing media : None known

- Specific hazards arising from the chemical:

                It may produce toxic fumes of carbon monoxide if burning.

                P260 Do not breathe fumes.

- Specific methods of fire-fighting:

                P381 Eliminate all ignition sources if safe to do so.

                Fight fire from the windward side with suitable extinguish media.

                Evacuate all non-essential personnel from affected area.

                Use water to cool fire-exposed containers and facilities.

- Special protective equipment and precautions for fire-fighters:

                Wear fire protective equipment.

Accidental release measures

a) Personal precautions : Wear appropriate respiratory protection. Use personal protective clothing. Avoid contact with the skin, eyes and clothing.

                                            In case of large spills, evacuate area.

                                            P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

b) Environmental precautions : Prevent product or liquids contaminated with product from entering sewers, drains, soil or open water course.

c) Methods and materials for containment and cleaning up :

 - [Large spills]                    Dike spilled material in an appropriate container for disposal or contact fire and emergency services for advice.

                                             Be careful to slip.

 - [Small spills] Add inert absorbent material (dry sand, earth, sawdust) and transfer material to an appropriate container for disposal.

d) Prevention of secondary accidents: Remove all sources of ignition and prepare suitable extinguishing media.

Handling and storage

- [Handling]

                   Technical Measures : Provide an emergency eye/face wash fountain and quick drench shower in the immediate work area.

                   Precautions : P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

                   Precautions for safe handling : Provide ventilation.

                                                                          Wear personal protective equipment.

                                                                          Avoid breathing of vapor or mist, avoid contact with eyes, skin and clothing.

- [Storage]

                  Conditions for safe storage : P403+233 Store in a well ventilated place (preferably indoor) and keep in the original container tightly

                  closed.Recommended storage temperatures: +15 to +25°C.

                  P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

                  Safe packaging materials : In accordance with the original product container.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not applicable
Shippingopen allclose all
Labels:
Not applicable
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not applicable
Shippingopen allclose all
Labels:
Not applicable
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not applicable
Shipping information
Proper shipping name and description:
Not applicable
Chemical name:
Not applicable
Labels:
Not applicable
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not applicable
Shipping information
Proper shipping name and description:
Not applicable
Chemical name:
Not applicable
Labels:
Not applicable
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

- Exposure limit values : No data available

- Control parameters : Not determined

- Engineering measures : Provide local exhaust ventilation in case it produces fume/gas/mist/vapours.

- Protective measures : Handle in accordance with good industrial hygiene and safety practices.

- Personal protection equipment: Provide an emergency eye/face wash fountain and quick drench shower in the immediate work area.

                  Respiratory protection : As appropriate to situation

                  Hands protection : Chemical resistant gloves

                  Eyes protection : Safety goggles

                  Body protection : Long sleeved work clothes

- Hygiene measures : Wash your hands thoroughly after handling

Stability and reactivity

a) Reactivity : No information available

b) Chemical stability : Stable under normal conditions

c) Possibility of hazardous reactions : No information available

d) Conditions to avoid : Superheating

e) Incompatible materials : No information available

f) Hazardous decomposition products : in the event of a fire (see section: “FIRE-FIGHTING MEASURES”)

Disposal considerations

Dispose of contents/container in accordance with local/regional/national/international regulations.