Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 266-267-2 | CAS number: 66230-21-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Hydrolysis
Administrative data
Link to relevant study record(s)
- Endpoint:
- hydrolysis
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 28.07.2014 - 22.10.2015
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.7 (Degradation: Abiotic Degradation: Hydrolysis as a Function of pH)
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 111 (Hydrolysis as a Function of pH)
- GLP compliance:
- yes
- Specific details on test material used for the study:
- Identification: CAS# 71077-09-3
Appearance/Physical State: Pale yellow liquid
Batch: 76200
Purity: 98.7%
Expiry Date: 30 April 2015
Storage Conditions: Room temperature in the dark - Radiolabelling:
- no
- Analytical monitoring:
- yes
- Buffers:
- Buffer solution (pH)
Components
Concentration
(mmol dm-3)
4
Citric acid
0.6
Sodium chloride
0.4
Sodium hydroxide
0.7
7
Disodium hydrogen orthophosphate (anhydrous)
0.3
Potassium dihydrogen orthophosphate
0.2
Sodium chloride
0.2
9
Disodium tetraborate
0.1
Sodium chloride
0.2 - Details on test conditions:
- Sample solutions were prepared in stoppered glass flasks at a nominal concentration of 0.50 mg/L in the three buffer solutions. A 1% co-solvent of acetonitrile was used to aid solubility.
The test solutions were split into individual vessels for each data point.
The solutions were shielded from light whilst maintained at the test temperature.
Sample solutions at pH 4, 7 and 9 were maintained at 70.0 ± 0.5 °C, 60.0 ± 0.5 °C, 50.0 ± 0.5 °C, 30.0 ± 0.5 °C and 20.0 ± 0.5 °C (as appropriate for each pH) for a suitable period of time in order to be able to calculate the half-life at each temperature.
3.5.2.2 Analysis of the Sample Solutions
The sample solutions were taken from the waterbath at various times and the pH of each solution recorded.
The concentration of the sample solution was determined by high performance liquid chromatography (HPLC). - Number of replicates:
- Duplicate aliquots (A and B) of each sample solution were diluted by a factor of two using methanol.
Sample blanks
Methanol: relevant pH buffer solution (50:50 v/v)
Standards
Standard solutions of test item were prepared in methanol: purified water (50:50 v/v) covering a nominal concentration range of 0 to 0.50 mg/L, with a check standard at nominally 0.25 mg/L.
Matrix blanks
Methanol: purified water (50:50 v/v) - Positive controls:
- not specified
- Negative controls:
- not specified
- Transformation products:
- yes
- No.:
- #1
- No.:
- #2
- Details on hydrolysis and appearance of transformation product(s):
- On discussions with the Sponsor, it was indicated that the test item is made by driving off water, and it is in equilibrium. Therefore, the ultimate hydrolysis products were considered to be the starting materials, isophorone diamine (IPDA) and methyl isobutyl ketone (MIBK).
- % Recovery:
- 41.4
- St. dev.:
- 5.6
- pH:
- 4
- Temp.:
- 50 °C
- Duration:
- 4 h
- % Recovery:
- 73.2
- St. dev.:
- 2.2
- pH:
- 4
- Temp.:
- 60 °C
- Duration:
- 4 h
- pH:
- 7
- Temp.:
- 20 °C
- Remarks on result:
- hydrolytically stable based on preliminary test
- pH:
- 7
- Temp.:
- 30 °C
- Remarks on result:
- hydrolytically stable based on preliminary test
- pH:
- 9
- Temp.:
- 20 °C
- Remarks on result:
- hydrolytically stable based on preliminary test
- pH:
- 9
- Temp.:
- 30 °C
- Remarks on result:
- hydrolytically stable based on preliminary test
- Key result
- pH:
- 4
- Temp.:
- 25 °C
- Hydrolysis rate constant:
- 0.138 h-1
- Type:
- (pseudo-)first order (= half-life)
- Validity criteria fulfilled:
- yes
- Conclusions:
- The rate constants and estimated half-lives at 25 °C of the test item are shown in the following table:
Table 3.16
pH
Rate constant (hr-1)
Estimated half-life at 25 °C
4
~ 0.138
~ 5 hours
7
-
< 2 hours
9
-
< 2 hours - Executive summary:
The sample blank solutions were noted to contain a significant response at approximately the retention time of the test item. Therefore, all of the sample concentrations have been corrected for the appropriate sample blank solution.
The detector response of the standards was noted to decrease over the course of the analysis runs. However, on review, the effect of this on the overall results was considered to be minor.
The limit of detection was somewhat variable run-to-run due to the method of detection (MS) used, but was based on approximately 2 times the baseline “noise” observed for the individual sample blank injections at approximately the retention time of the test item.
On comparison to the initial hydrolysis testing (see Appendix 3), the main difference was that the individual components of the test item could be seen in the chromatograms. The main problem with this was that the limit-of-quantitation was now much higher than that for the preliminary testing, with the result that rapid losses of test item due to hydrolysis quickly made most, if not all of the sample results, “none detected”.
The kinetics of the study has been determined to be consistent with that of a pseudo-first order reaction as the graphs of log10 concentration versus time are essentially straight lines.
It has been observed that the rate of hydrolysis increases with an increase in pH.
Reference
Description of key information
Key value for chemical safety assessment
- Half-life for hydrolysis:
- 2 h
- at the temperature of:
- 25 °C
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.