Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019-03-27 to 2019-05-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
effusion method: vapour pressure balance
Key result
Temp.:
25 °C
Vapour pressure:
0.05 Pa

Laboratory equipment

DSC 1 Star, DSC No. 5, Mettler Toledo

Micro Balance MX5, Mettler-Toledo GmbH

Oxyhydrogen flame generated by the apparatus Typ 160 N, Aquarius GmbH

Vapour Pressure balance

Vacuum pressure balance 433 (Netzsch GmbH)

Controller 413 (Netzsch GmbH)

Micro balance (Cahn)

Recorder Gila (Geb. Laumann)

Vacuum pump Duo 30A (Balzers Instr.)

Turbo Molecular Pump (Balzers Instr.)

Pump Controller TCP 380 (Balzers Instr.)

Precision Balance EX 6202/E, Ohaus

Conclusions:
The vapour pressure of the test substance at 25°C is: 0.05 Pa.

Description of key information

The vapour pressure of the test substance at 25°C is: 0.05 Pa.

Key value for chemical safety assessment

Vapour pressure:
0.05 Pa
at the temperature of:
25 °C

Additional information