First-aid measures

Description of first aid measures

Remove contaminated clothing.

If inhaled:

Keep patient calm, remove to fresh air.

On skin contact:

Wash thoroughly with soap and water.

On contact with eyes:

Wash affected eyes for at least 15 minutes under running water with eyelids held open.

On ingestion:

Rinse mouth and then drink plenty of water.

Indication of any immediate medical attention and special treatment needed

Treatment: Symptomatic treatment (decontamination, vital functions).

Fire-fighting measures

Extinguishing media

Suitable extinguishing media:

water spray, dry powder, alcohol-resistant foam, carbon dioxide

Special hazards arising from the substance or mixture

carbon oxides

The substances/groups of substances mentioned can be released in case of fire.

Advice for fire-fighters

Special protective equipment:

Wear a self-contained breathing apparatus.

Further information:

Collect contaminated extinguishing water separately, do not allow to reach sewage or effluent

systems. Dispose of fire debris and contaminated extinguishing water in accordance with official

regulations.

Accidental release measures

Personal precautions, protective equipment and emergency procedures

Handle in accordance with good industrial hygiene and safety practice.

Environmental precautions

Discharge into the environment must be avoided. Do not empty into drains.

Methods and material for containment and cleaning up

For large amounts: Pump off product.

For residues: Pick up with suitable absorbent material (e.g. sand, sawdust, general-purpose binder,

kieselguhr). Dispose of absorbed material in accordance with regulations.

Handling and storage

Precautions for safe handling

Ensure thorough ventilation of stores and work areas.

Protection against fire and explosion:

Take precautionary measures against static discharges. Keep away from sources of ignition - No

smoking. Electrical devices must meet the specified temperature class.

Temperature class: T2 (Autoignition temperature >300 °C).

Conditions for safe storage, including any incompatibilities

Further information on storage conditions: Keep container tightly closed and dry; store in a cool place.

Protect from air. Protect from atmospheric humidity. Protect contents from the effects of light.

Storage stability:

Storage temperature: <= 40 °C

Storage duration: 24 Months

The stated storage temperature should be noted.

From the data on storage duration in this safety data sheet no agreed statement regarding the

warrantee of application properties can be deduced.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure controls

Personal protective equipment

Hand protection:

Suitable materials also with prolonged, direct contact (Recommended: Protective index 6,

corresponding > 480 minutes of permeation time according to EN 374):

fluoroelastomer (FKM) - 0.7 mm coating thickness

butyl rubber (butyl) - 0.7 mm coating thickness

polyvinylchloride (PVC) - 0.8 mm

nitrile rubber (NBR) - 0.4 mm coating thickness

chloroprene rubber (CR) - 0.5 mm coating thickness

Suitable materials short-term contact and/or splashes (recommended: At least protective index 2,

corresponding > 30 minutes of permeation time according to EN 374)

natural rubber/natural latex (NR) - 0.5 mm coating thickness

Supplementary note: The specifications are based on tests, literature data and information of glove

manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g.

temperature) it must be considered, that the practical usage of a chemical-protective glove in practice

may be much shorter than the permeation time determined through testing.

Manufacturer's directions for use should be observed because of great diversity of types.

Eye protection:

Safety glasses with side-shields (frame goggles) (e.g. EN 166)

General safety and hygiene measures

Handle in accordance with good industrial hygiene and safety practice. Wearing of closed work

clothing is required additionally to the stated personal protection equipment.

Stability and reactivity

Reactivity

Corrosion to metals: Corrosive effects to metal are not anticipated.

Formation of

flammable gases:

Remarks: Forms no flammable gases in the

presence of water.

Chemical stability

The product is stable if stored and handled as prescribed/indicated.

Possibility of hazardous reactions

No hazardous reactions if stored and handled as prescribed/indicated.

Conditions to avoid

Temperature: > 40 °C

Avoid daylight. Disregard of the conditions mentioned may result in undesirable decomposition

reactions.

Incompatible materials

Substances to avoid:

zinc, strong oxidizing agents

Hazardous decomposition products

Possible decomposition products:

carbonyl compounds

Disposal considerations

Waste treatment methods

Incinerate in suitable incineration plant, observing local authority regulations.

A waste code in accordance with the European waste catalog (EWC) cannot be specified, due to

dependence on the usage.

The waste code in accordance with the European waste catalog (EWC) must be specified in

cooperation with disposal agency/manufacturer/authorities.

Contaminated packaging:

Contaminated packaging should be emptied as far as possible and disposed of in accordance with

official regulations after being thoroughly cleaned.