Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1998
Report date:
1998

Materials and methods

Test guideline
Qualifier:
no guideline available
Principles of method if other than guideline:
The DSC thermal decomposition experiment was run at a 10 °C/minute heating ramp. The sample was sealed in a hermetic gold lined stainless steel container.
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

For thermal stability study

Test substance thermally stable:
yes
Operating temperature
Operating temp.:
30 - 180 °C
Sublimation:
not determined
Transformation products:
not measured

Any other information on results incl. tables

The experiment was run twice, and in both cases the sample leaked out of the container. This is unusual, suggesting an interaction of the sample with the gold plated seal. No thermal events were observed from 30°C to 180°C. Above 180°C leakage occurred.

Applicant's summary and conclusion

Conclusions:
The substance is stable up to 180°C