Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 848-720-1 | CAS number: 1616494-50-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Density
Administrative data
Link to relevant study record(s)
- Endpoint:
- density, other
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 02/10/2019
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- comparable to guideline study with acceptable restrictions
- Qualifier:
- according to guideline
- Guideline:
- other: ASTM D4052
- Principles of method if other than guideline:
- Viscosity is a measure of the resistance of a fluid which is being deformed by either shear stress or tensile stress. The Kinematic viscosity is the dynamic (absolute) viscosity divided by the density. The API gravity is equivalent to the density of the product at a specified temperature, in this case 15 ºC. The test sample DE11657 (10 mL) was loaded into a plastic syringe then 8 mL of sample was flushed through the machine (Anton PAAR Stabinger SVM 3001 Viscometer). The ‘viscosity index’ method was run and an extra 1 mL of sample was flushed through the machine, as instructed, before the measurements began. The viscosity and density of the sample was measured at 40 and 100 ºC, respectively then the API gravity at 15 ºC was automatically calculated.
- GLP compliance:
- no
- Type of method:
- other: Anton PAAR Stabinger SVM 3001 Viscometer ( Couette measuring principle)
- Type:
- other: API gravity
- Remarks:
- The API gravity is equivalent to the density of the product at a specified temperature, in this case 15 ºC
- Density:
- ca. 0.871 g/cm³
- Temp.:
- 15 °C
- Executive summary:
The API gravity is equivalent to the density of the product at a specified temperature, in this case 15 ºC, the API gravity(/density) was conluded as 0.8708 g/cm3
Reference
Description of key information
Key value for chemical safety assessment
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.