Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
ca. 178 °C
Atm. press.:
ca. 1 atm

Temperature ramp rate: 5 to 6 ºC/min

           Stirring rate: 90 to 120 revolutions/min

Application Frequency of Ignition Source for expected flash points above 110ºC: at each temperature increase of 2ºC beginning at a temperature 18 to 28ºC below the expected flash point

Interpretation of results:
GHS criteria not met
Conclusions:

The Pensky-Martens Close Cup Flash Point of 138492 is 178.0ºC.
Executive summary:

The Pensky-Martens Close Cup Flash Point of 138492 is 178.0ºC.

Description of key information

The Pensky-Martens Close Cup Flash Point of 138492 is 178.0ºC

Key value for chemical safety assessment

Flash point at 101 325 Pa:
178 °C

Additional information