Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Qualifier:
according to guideline
Guideline:
other: VDI guideline 2263 part 1, 1190
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Methyl 4-cyano-5-[[5-cyano-2,6-bis[(3-methoxypropyl)amino]-4-methyl-3-pyridyl]azo]-3-methyl-2-thenoate
EC Number:
277-146-9
EC Name:
Methyl 4-cyano-5-[[5-cyano-2,6-bis[(3-methoxypropyl)amino]-4-methyl-3-pyridyl]azo]-3-methyl-2-thenoate
Cas Number:
72968-71-9
Molecular formula:
C23H29N7O4S
IUPAC Name:
methyl 4-cyano-5-[[5-cyano-2,6-bis[(3-methoxypropyl)amino]-4-methyl-3-pyridyl]azo]-3-methyl-2-thenoate
impurity 1
Reference substance name:
Unknown impurity
Molecular formula:
not available
IUPAC Name:
Unknown impurity
Test material form:
solid: particulate/powder
Details on test material:
Macrolex Rot B, batch CHA009
Identity and content reported in study 2015/0125/01 (CURRENTA GmbH & Co. OHG; March 3, 2016)
Purity: 99.7 %
Specific details on test material used for the study:
Instead of the oven described in test procedure A.16 the Grewer oven (VDI guideline 2263, part 1, 1990) was used. Both ovens are similar and the results are comparable.

Results and discussion

Relative self-ignition temperature (solids)
Remarks on result:
other: No exothermic reaction and no self-ignition was observed up to the melting point.

Any other information on results incl. tables

In the temperature/time-diagram two weak endothermic effects were observed.

The first one is in the range from 168 to 178 °C and the second one in the range from 220 to 231 °C. At the end of the measurements the basket was empty. No exothermic reaction and no self-ignition was observed. These findings correspond with the result from the melting temperature measurement.

Applicant's summary and conclusion

Conclusions:
Macrolex Rot B does not undergo spontaneous combustion.
Executive summary:

The relative self-ignition temperature of Macrolex Rot B was investigated according to EC Test Procedure A.16 'Relative self-ignition temperature for solids'.

In the temperature/time-diagram two weak endothermic effects were observed. The first one is in the range from 168 to 178 °C and the second one in the range from 220 to 231 °C. At the end of the measurements the basket was empty. No exothermic reaction and no self-ignition was observed. These findings correspond with the result from the melting temperature measurement. Thus, it can be concluded that Macrolex Rot B does not undergo spontaneous combustion (BTS 2018).