First-aid measures

General advice: Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled: If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact: Wash off with soap and plenty of water. Consult a physician.
In case of eye contact: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed: Do not induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Fire-fighting measures

Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Advice for firefighters: Wear self-contained breathing apparatus for firefighting if necessary.
Further information: Use water spray to cool unopened containers.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Use personal protective equipment. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.

Personal protective equipment:
Eye/face protection: Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection: Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Body Protection: Impervious clothing, Flame retardant antistatic protective clothing., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Respiratory protection: Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Environmental precautions: Prevent further leakage or spillage if safe to do so. Do not let product enter drains.

Methods and materials for containment and cleaning up Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet-brushing and place in container for disposal according to local regulations.

Handling and storage

Precautions for safe handling:
Avoid contact with skin and eyes. Avoid inhalation of vapour or mist. Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic charge.
Conditions for safe storage, including any incompatibilities:
Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
2943
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
2943
Shipping information
Proper shipping name and description:
TETRAHYDROFURFURYLAMINE
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
2943
Shipping information
Proper shipping name and description:
Tetrahydrofurfurylamine
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Normal operation
Workers use PPE as a good practice to minimise possible exposures from minor accidental leaks during loading and unloading the reaction vessel, even though rigorous containment is ensured through technical means. Procedures are in place for disposal or cleaning of contaminated PPE.
Accident and incidents
A fully trained Emergency Response Team (ERT) is in place to react in case of accidents and incidents resulting in unexpected releases of the intermediate in order to minimize risks of exposures to humans and the environment. Components of the ERT are selected among senior site operators and technicians and are periodically trained and certified to respond to emergencies. Trainings and certifications of members ERT are subject to periodical revisions and approval by Local Fire Department. PPE as specified in emergency procedures and training are required in case of accidents and incidents. Procedures are in place for disposal or cleaning of contaminated PPE, as appropriate.
Maintenance and cleaning
Workers use additional PPE for cleaning the reaction vessel. A short exposure may occur during a maintenance operation, involving opening of a section of the pipeline connecting the reactor with loading station due to accidental presence of a residue of diluted intermediate that may lead to skin exposure. As a result, workers are given a specific work instruction on how to open this section, and are required to use high-efficiency PPE for skin and respiratory protection, as a precautionary and protective measure during all maintenance work, where there is a potential for exposure. PPE type is specified in the permit-to-work documents. Procedures are in place for disposal or cleaning of contaminated PPE, as appropriate.

Stability and reactivity

Disposal considerations