Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
other: handbook data
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data

Data source

Reference
Reference Type:
review article or handbook
Title:
Military Explosives
Author:
United States Army
Year:
1984
Bibliographic source:
Technical Manual 9-1300-214. Headquaters, Department of the Army, September 1984, p.7-9 to 7-11

Materials and methods

Principles of method if other than guideline:
In this Technical Manual the granulation is reported.
GLP compliance:
not specified
Other quality assurance:
other: reliable handbook data
Type of method:
other: not reported

Test material

1
Chemical structure
Reference substance name:
1,4-dihydro-5,7-dinitrobenzofurazan-4-ol 3-oxide, potassium salt
EC Number:
249-543-7
EC Name:
1,4-dihydro-5,7-dinitrobenzofurazan-4-ol 3-oxide, potassium salt
Cas Number:
29267-75-2
Molecular formula:
C6H3N4O7.K
IUPAC Name:
4,6-Dinitro-7-hydro-7-hydroxy-1-oxido-2,1,3-benzoxadiazol-1-ium-at, Kaliumsalz
Test material form:
solid

Results and discussion

Particle size distribution at different passages
Size:
>= 0.053 - <= 0.297 mm
Remarks on result:
other: Particle size distribution was determined to be in the range >= 0.053 - <= 0.297 mm.
Remarks:
Particle size distribution determined by sieving through No. 50, No. 100, No. 200 and No. 270 US standard sieves (see under overall remarks).

Applicant's summary and conclusion

Conclusions:
The particle size of the test item is in the range between 0.053 mm and 0.297 mm.
Executive summary:

In the Technical Manual, the particle size distribution of the test item determined by sieving is reported: 98% at minimum passed through a No. 50 US standard sieve, 96% through a No. 100 US standard sieve, 25 -90% through a No. 200 US standard sieve, and 0 -15% through a No. 270 US standard sieve. Based on these information, it can be concluded that the test item particle size is in the range between 0.297 mm (corresponding to a No. 50 US standard sieve) and 0.053 mm (corresponding to a No. 270 US standard sieve).