Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012-02-22 - 2012-03-15
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks:
Pensky-Martens closed cup apparatus
Dynamic viscosity of test material:
No data available.
Data not required for Reach registartion at tonnage 1-10 tpa.
Specific details on test material used for the study:
- Batch n°: PFW090017
- Date CoA: 27.10.2011
- Water content: 0.12%
- Test Substance Name Jeffamine EDR-176
- Chemical Name 3,3-etheylenedioxybis(propylamine)
- CAS number 2997-01-5
- Batch Number PFW090017
- Description Colourless liquid
- Molecular Formula C8H20N2O2
- Molecular Weight 176 g.mol-1
Key result
Flash point:
138.5 °C
Atm. press.:
101.325 kPa
Remarks on result:
other: 138.5°C (corrected for barometric pressure)

Full test results:

 Temperature °C Barometric Pressure (kPa)  Ignition Yes (y) / No (n) 

Halo/Enlarged test

flame?

Yes (y) / No (n)

 116   102.7  n  n
 118   102.7  n  n
 120   102.7  n  n
 122   102.7  n  n
 124   102.7  n  n
 126   102.7  n
 128

  102.7

 n  n
 130   102.7  n  n
132    102.7  n  n
 134   102.7  n  n
 136   102.7  n  y
 138   102.7  n  y
 140   102.7  y  N/A
          Fresh sample
 117  102.6  n  n
 119  102.6  n  n
 121   102.6  n  n
 123   102.6  n  n
 125   102.6  n  n
 127   102.6  n  n
 129   102.6  n  n
 131   102.6  n  n
 133   102.6  n  n
 135   102.6  n  n
 137   102.6  n  y
 139   102.6  y  N/A

Closed cup Flash point Temperature: 138.5°c (corrected for barometric pressure)

Interpretation of results:
GHS criteria not met
Conclusions:
Closed Cup Flash Point Temperature : 138.5°C (corrected for barometric pressure).
Executive summary:

The flash point determination test is conducted in accordance with the procedure described in EU Regulation (EC) 440/2008, Annex Part A test A9.

The Closed Cup Flash Point Temperature was found to be 138.5°C (corrected for barometric pressure).

Description of key information

The flash point determination test is conducted in accordance with the procedure described in EU Regulation (EC) 440/2008, Annex Part A test A9.

The Closed Cup Flash Point Temperature was found to be 138.5°C (corrected for barometric pressure).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
138.5 °C

Additional information