Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
bulk density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
The Anton PAAR method of density measurement was used.
Deviations:
not specified
Principles of method if other than guideline:
A hollow U-shaped tube is electromagnetically forced into harmonic oscillation. The period of oscillation is dependent on the density of the sample in the tube. Therefore, by measuring the period of oscillation, the density or density related values are automatically calculated.
GLP compliance:
not specified
Type of method:
oscillating densitimeter

Test material

Constituent 1
Chemical structure
Reference substance name:
ethyl 2-{[(1R,2S,5R)-5-methyl-2-(propan-2-yl)cyclohexyl]formamido}acetate
EC Number:
695-735-2
Cas Number:
68489-14-5
Molecular formula:
C15H27NO3
IUPAC Name:
ethyl 2-{[(1R,2S,5R)-5-methyl-2-(propan-2-yl)cyclohexyl]formamido}acetate

Results and discussion

Density
Type:
bulk density
Density:
ca. 5.87 kg/m³
Remarks on result:
other: Standard conditions (room temperature) assumed.

Applicant's summary and conclusion

Conclusions:
The relative density of the test item was 5.87 kg/m3 .
Executive summary:

The relative density of the test item was determined according to the OECD TG 109 and it was was 5.87 kg/m3 .