Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Eye Contact: Flush eyes with water for at least 15 minutes. Get medical attention if eye irritation develops or persists.
Skin Contact: Remove contaminated clothing and shoes. Wash off with warm water and soap.
Ingestion: Rinse mouth. Induce vomiting by ingestion of big amount of product only.
Inhalation: Remove person to fresh air. If signs/symptoms continue, get medical attention.
- Indication of immediate medical attention and special treatment needed
Notes to Physician: Treat symptomatically.

Fire-fighting measures

- Extinguishing media:
Suitable Extinguishing Media: Water mist. Foam.
Unsuitable extinguishing media: Compressed carbon dioxide - danger of dust generation.
- Special hazards arising from the substance or mixture:
Avoid dust generaration (organic dust can be initiate static electricity).
- Advice for firefighters
Special protective equipment for firefighters: As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

Accidental release measures

- Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid contact with dusts/fumes/mists/vapors. Avoid all unnecessary contact.
For non-emergency personnel:
Emergency procedures: Evacuate the danger area and alert emergency team.
- Environmental Precautions:
Prevent entry into waterways, sewers, basements or confined areas. Prevent further leakage or spillage if safe to do so. Report according to local regulations.
- Methods and materials for containment and cleaning up:
For cleaning up: Clean up mechanically, sweep up carefully, and collect in duplicate, entire labelled packing (PE bag, drum, container). Wash place of spillage with 8% acetic acid and water.

Handling and storage

- Precautions for Safe Handling:
Handling: Handle with substance only in original and closed package. Wear personal protective equipment.
Hygiene Measures: Handle in accordance with good industrial hygiene and safety practice.
- Conditions for safe storage, including any incompatibilities:
Store in original container. Protect from light. Store in a dry place and/or in closed container. Store with temperature up to +25 °C. Do not store with flammables.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

- Control parameters:
Exposure Limits: Authority in the Czech Republic determined for this product a maximum acceptable air concentration value: NPK 0,001 mg/m3
Exposure controls:
Engineering Measures: Provide engineering control, according to Company Guidelines. Ensure adequate ventilation, especially in confined areas. Local containment solutions. (LEV, downflow booth, direct connections or other enclosure e.g. inflatable seal).
Special Requirements: Weigh in laminar box only. Use closed technology. Before breaks and after handling wash
thoroughly hands. In laboratory handle within a chemical or weighing hood or use other ventilated enclosure.
Personal protective equipment:
- Eye/face protection: Approved safety goggles/glasses. Full face mask, hood or goggles.
- Skin protection: - Body protection Long sleeved clothing. Closed work shoes. Disposable garment (e.g. Tyvek), shoes covers and enclosed shoes.
- Hand protection Rubber gloves. Double gloves.
- Respiratory Protection Approved full face respirator P3 or airline respirator. In controlled containment respiratory protection dependent on IH monitoring.
- Recommended Filter type: P3.
Environmental exposure controls: Contaminated protective equipments must be considered as dangerous waste.

Stability and reactivity

- Reactivity: No information available.
- Chemical Stability: Stable under normal conditions.
- Possibility of hazardous reactions: None under normal processing.
- Conditions to avoid: High temperature.
- Incompatible materials: No information available.
- Hazardous decomposition products: Combustion may emit toxic and choking fumes of: carbon oxides, nitrogen oxides (NOx).

Disposal considerations

- Waste treatment methods
Waste from Residues/Unused Products: Can be incinerated, when in compliance with local regulations. Before incineration, humidify the substance.
Contaminated Packaging: Contaminated package must be disposed as residue of substance.