Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Cross-reference
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
sulfuric acid hydrate
EC Number:
922-670-1
IUPAC Name:
sulfuric acid hydrate
Details on test material:
representative sample selected and collected according to REACH Copper Consortium Protocol (see Iuclud 4.1 & 1.4)
Test item AC_B13_625875

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
> 400 °C
Remarks on result:
other: The test item has been determined not to have an auto ignition temperature below 400°C

Applicant's summary and conclusion

Conclusions:
GLP study was conducted with representative sample. The test item has been determined not to have an auto ignition temperature below 400°C
Executive summary:

The test item has been determined not to have an auto ignition temperature below 400°C