Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
This study was conducted between 21 July 2016 and 26 July 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
30 May 2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
100.91 °C
Atm. press.:
101.7 kPa
Remarks on result:
no flash point up to 100°C

Results of the flash point determination are shown in the following table.

Test Temperature (ºC)       Observations

23.0                                   No flash.

28.0                                   No flash.

33.0                                   No flash.

38.0                                   No flash.

43.0                                   No flash.

48.0                                   No flash.

53.0                                   No flash.

58.0                                   No flash.

63.0                                   No flash.

68.0                                   No flash.

73.0                                   No flash.

73.0 (fresh sample)             No flash.

78.0                                   No flash.

83.0                                   No flash.

88.0                                   No flash.

93.0                                   No flash.

98.0                                   No flash.

103.0 (fresh sample)           A blue flash spread across the sample cup.

98.0 (fresh sample)             No flash.

99.0 (fresh sample)             No flash.

100.0 (fresh sample)        No flash.

101.0 (fresh sample)        A blue flash spread across the sample cup.

101.0 (fresh sample)        A blue flash spread across the sample cup.

99.0 (fresh sample)        No flash.

Interpretation of results:
study cannot be used for classification
Conclusions:
The flash point of the test item has been determined to be 101 ± 2 °C.
Executive summary:

The hazardous physico-chemical properties of FRET 10-0367 have been determined.

Flash Point.

101 ± 2 °C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

Flash Point. 101 ± 2 °C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
101 °C

Additional information

The flash point of the test item has been determined to be 101 ± 2 °C.