Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From February 2nd to February 3rd, 2016.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: Knudsen cell
Remarks:
(Knudsen cell)
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0 Pa
Key result
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
0 Pa

Vapour pressure of TSA at 20 ºC and 25 ºC was calculated on the basis of equation log (p) = f (1/t) = a-b/(t+273.15) where: p – vapour pressure in Pa, t – temperature in ºC, obtained for four measurement points: 25.3 ºC, 27.7 ºC, 30.2 ºC and 32.8 ºC.

The determined vapour pressure is:

Vapour pressure

at 20ºC[Pa]

Vapour pressure

at 25ºC[Pa]

9.41·10-08

2.81·10-07

Conclusions:
The vapour pressure of the test substance is 9.41E-08 Pa at 20ºC and 2.81E-07 Pa at 25ºC.
Executive summary:

The study of vapour pressure using effusion method was performed in accordance with the method EEC A4 (Knudsen cell), with GLP. The vapour pressure of the test substance was determined to be 9.41E-08 Pa at 20ºC and 2.81E-07 Pa at 25ºC.

Description of key information

Key study. Method according to OECD 104 / EU Method A.4 (Knudsen cell), GLP study. The vapour pressure of the test item at 20ºC is 9.41E-08 Pa, and the vapour pressure of the test item at 25ºC is 2.81E-07 Pa.


Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
20 °C

Additional information