Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Data is from experimental study
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker. The principle includes measurement of relative amounts of particles present, sorted according to size
GLP compliance:
no
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
counted distribution
Key result
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
No.:
#1
Size:
106 µm
Distribution:
26.904 %
No.:
#2
Size:
75 µm
Distribution:
68.086 %
No.:
#3
Size:
53 µm
Distribution:
3.691 %
No.:
#4
Size:
25 µm
Distribution:
1.318 %

OBSERVATION TABLE:

Amount of test item weighed (g)=10.001 g

Method run time(minute)=10 min

Sieve sizes(in microns)

Weight of petridishes + test item(g)  Test item quantity retained after sieving (g)   Percentage(%)of test item*

150 microns

 -

 0

 0.0000

106 microns

56.613 

2.653 

26.9039 

75 microns

 48.380

 6.714

 68.0864

53 microns

 51.232

 0.364

 3.6913

 25 microns

 44.638

 0.13

 1.3183

 10 microns

 -

 0

0.0000 

  Bottom Pan

 -

 0

 0.0000

Conclusions:
The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker. The particle size distribution was determined to be in the range of 106 micron to 25 micron.
Executive summary:

The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker. The particle size distribution was found to bein the range of 106 micron to 25 micron.

Description of key information

The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker. The particle size distribution was determined to be in the range of 106 micron to 25 micron.

Additional information

The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker. The particle size distribution was determined to be in the range of 106 micron to 25 micron.