Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Testing was conducted between 12 June 2008 and 10 July 2008.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP and in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not effect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
The work described was performed in compliance with UK GLP standards (Schedule 1, Good Laboratory Practice Regulations 1999 (SI 1999/3106 as amended by SI 2004/0994)).
Type of method:
effusion method: vapour pressure balance

Test material

Results and discussion

Vapour pressure
Temp.:
25 °C
Vapour pressure:
< 0 Pa

Any other information on results incl. tables

Run 1

Temperature (ºC)

Temperature (K)

Reciprocal Temperature (K-1)

Mass Difference (µg)

Mass Difference (kg)

Vapour Pressure (Pa)

Log10 Vp

120

393.15

0.002543558

1.46

1.460E-09

0.002026854

-2.693177523

121

394.15

0.002537105

1.30

1.300E-09

0.001804733

-2.743587026

122

395.15

0.002530685

2.28

2.280E-09

0.003165224

-2.499595532

123

396.15

0.002524296

0.65

6.500E-10

0.000902367

-3.044617022

124

397.15

0.002517940

1.95

1.950E-09

0.002707100

-2.567495767

125

398.15

0.002511616

2.60

2.600E-09

0.003609466

-2.442557031

126

399.15

0.002505324

2.20

2.200E-09

0.003054164

-2.515107698

127

400.15

0.002499063

1.46

1.460E-09

0.002026854

-2.693177523

128

401.15

0.002492833

0.81

8.100E-10

0.001124488

-2.949045360

129

402.15

0.002486634

0.98

9.800E-10

0.001360491

-2.866304303

130

403.15

0.002480466

1.06

1.060E-09

0.001471552

-2.832224513

No statistical analysis is given due to the nature of the plot

Run 2

Temperature (ºC)

Temperature (K)

Reciprocal Temperature (K-1)

Mass Difference (µg)

Mass Difference (kg)

Vapour Pressure (Pa)

Log10 Vp

120

393.15

0.002543558

0.73

7.300E-10

0.001013427

-2.994207519

121

394.15

0.002537105

0.73

7.300E-10

0.001013427

-2.994207519

122

395.15

0.002530685

1.55

1.550E-09

0.002151797

-2.667198681

123

396.15

0.002524296

0.98

9.800E-10

0.001360491

-2.866304303

124

397.15

0.002517940

0.08

8.000E-11

0.000111060

-3.954440392

125

398.15

0.002511616

1.55

1.550E-09

0.002151797

-2.667198681

126

399.15

0.002505324

-0.57

-5.700E-10

-

-

127

400.15

0.002499063

1.46

1.460E-09

0.002026854

-2.693177523

128

401.15

0.002492833

0.73

7.300E-10

0.001013427

-2.994207519

129

402.15

0.002486634

0.65

6.500E-10

0.000902367

-3.044617022

130

403.15

0.002480466

0.81

8.100E-10

0.001124488

-2.949045360

No statistical analysis is given due to the nature of the plot


 


Run 3

Temperature (ºC)

Temperature (K)

Reciprocal Temperature (K-1)

Mass Difference (µg)

Mass Difference (kg)

Vapour Pressure (Pa)

Log10 Vp

120

393.15

0.002543558

1.22

1.220E-09

0.001693673

-2.771170548

121

394.15

0.002537105

1.22

1.220E-09

0.001693673

-2.771170548

122

395.15

0.002530685

0.81

8.100E-10

0.001124488

-2.949045360

123

396.15

0.002524296

0.81

8.100E-10

0.001124488

-2.949045360

124

397.15

0.002517940

0.98

9.800E-10

0.001360491

-2.866304303

125

398.15

0.002511616

1.22

1.220E-09

0.001693673

-2.771170548

126

399.15

0.002505324

1.06

1.060E-09

0.001471552

-2.832224513

127

400.15

0.002499063

-0.16

-1.600E-10

-

-

128

401.15

0.002492833

1.38

1.380E-09

0.001915794

-2.717651292

129

402.15

0.002486634

1.38

1.380E-09

0.001915794

-2.717651292

130

403.15

0.002480466

0.41

4.100E-10

0.000569185

-3.244746522

No statistical analysis is given due to the nature of the plot


 


Run 4

Temperature (ºC)

Temperature (K)

Reciprocal Temperature (K-1)

Mass Difference (µg)

Mass Difference (kg)

Vapour Pressure (Pa)

Log10 Vp

120

393.15

0.002543558

0.81

8.100E-10

0.001124488

-2.949045360

121

394.15

0.002537105

0.33

3.300E-10

0.000458125

-3.339016439

122

395.15

0.002530685

0.33

3.300E-10

0.000458125

-3.339016439

123

396.15

0.002524296

0.57

5.700E-10

0.000791306

-3.101655523

124

397.15

0.002517940

-0.16

-1.600E-10

-

-

125

398.15

0.002511616

0.81

8.100E-10

0.001124488

-2.949045360

126

399.15

0.002505324

0.65

6.500E-10

0.000902367

-3.044617022

127

400.15

0.002499063

1.87

1.870E-09

0.002596039

-2.585688772

128

401.15

0.002492833

0.90

9.000E-10

0.001249431

-2.903287869

129

402.15

0.002486634

0.65

6.500E-10

0.000902367

-3.044617022

130

403.15

0.002480466

1.14

1.140E-09

0.001582612

-2.800625527

No statistical analysis is given due to the nature of the plot

Discussion

No statistical analyses were performed because the balance readings were too low and variable for a line of best fit to have any meaning.  Instead it was considered more appropriate to impose a regression slope on a chosen data point to provide an estimate of the maximum value for the vapour pressure at 25ºC.

Run 4 was chosen because the sample had been under vacuum for the longest period prior to this run and so degassing would have been the most complete.  The reading at 127ºC (400.15 K) was chosen because this is the data point which gives the highest estimated vapour pressure at any given temperature when a slope of -1500 K is imposed upon it.

The value of -1500 K is an in-house value and is the shallowest slope observed whilst determining the vapour pressure on a wide range of samples using the vapour pressure balance method.  Extrapolation to 25ºC gave a vapour pressure of 1.355 x 10-4 Pa which has been taken as a maximum for this material.

The test material did not change in appearance under the conditions used in the determination.

Conclusion

The vapour pressure of the test material has been determined to be less than 1.4 x 10-4 Pa at 25ºC.

Applicant's summary and conclusion

Conclusions:
The vapour pressure of the test material has been determined to be less than 1.4 x 10-4 Pa at 25ºC.
Executive summary:

The vapour pressure for substance NDS-Li in project number 1307 -0448 was determined using a vapour pressure balance with measurements being made at several temperatures and linear regression analysis used to calculate the vapour pressure at 25°C.  Testing was conducted using Method A4 of Commission Directive 92/69/EEC (which constitutes Annex V of Council Directive 67/548/EEC).

The vapour pressure of the test material has been determined to be less than 1.4 x 10-4 Pa at 25ºC.