Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 939-719-8 | CAS number: 5502-75-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flash point
Administrative data
Link to relevant study record(s)
- Endpoint:
- flash point of flammable liquids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2004
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Justification for type of information:
- The study was conducted according to an internationally recognised method, and under GLP. No deviation was reported. Substance ID is adequately specified with purity. Therefore full validation applies.
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.9 (Flash-Point)
- Deviations:
- not specified
- Qualifier:
- according to guideline
- Guideline:
- ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
- Version / remarks:
- 1983
- Deviations:
- not specified
- Qualifier:
- according to guideline
- Guideline:
- ASTM D3278 (Standard test methods for flash point of liquids by small scale closed-cup apparatus)
- Version / remarks:
- 96
- Deviations:
- not specified
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Swiss Federal Office of Public Health (inspected on September 09 and 30, 2002 / signed on December 2002
- Type of method:
- equilibrium method closed cup
- Key result
- Flash point:
- 109 °C
- Atm. press.:
- 101.325 kPa
- Flash point:
- 108 °C
- Atm. press.:
- 97 kPa
- Interpretation of results:
- GHS criteria not met
- Remarks:
- GHS and EU-CLP criteria not met
- Conclusions:
- Flash point: 109ºC
The substance is NOT classified as flammable liquid according to CLP criteria (>60°C) or GHS criteria (> 93°C) - Executive summary:
The flash point of the test substance was measured under GLP according to ISO 3679 (listed in EU A9 guideline), rapid equilibrium closed cup method. The test was carried out in duplicate, and the mean measured value was corrected to normal atmospheric pressure. .
The normal flash point of test substance has been determined to be 109 ±2°C.
Reference
The measured flash temperature was corrected to a pressure of 101.325 kPa using equation of
FP = C + 0.23*(101.325-B)
FP: corrected flashpoint
C: observed flashpoint (118ºC)
B = ambient atmospheric pressure (97.0 kPa)
Description of key information
The substance is NOT classified as flammable liquid according to CLP Regulation or GHS criteria.
Key value for chemical safety assessment
- Flash point at 101 325 Pa:
- 109 °C
Additional information
A fully reliable experimental study, conducted under GLP according to a recognized EU/ISO method, is available. It is considered as a key study, and the result is retained as key data.
This study is relevant for the classification regarding flammable properties.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.