Administrative data

Endpoint:
bulk density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study was selected as a key study because the information provided for the hazard endpoint is sufficient for the purpose of classification and labelling and/or risk assessment.
Cross-reference
Reason / purpose for cross-reference:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
Sec. 10
Qualifier:
equivalent or similar to guideline
Guideline:
other: ASTM Method D501-03 Sec. 31
GLP compliance:
yes
Type of method:
air comparison pycnometer (for solids)

Test material

Constituent 1
Details on test material:
- Purity: not reported as such

Results and discussion

Density
Type:
bulk density
Density:
1.39 other: g/mL
Temp.:
24 °C

Applicant's summary and conclusion

Conclusions:
Bulk Density = 1.39 g/mL at 24ºC
The study and the conclusions which are drawn from it fulfil the quality criteria (validity, reliability, repeatability).
Executive summary:

Bulk Density = 1.39 g/mL at 24ºC