Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: No deviation from A.9 guideline, GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2002

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
non-equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: semi-solid at ambiant temperature
Details on test material:
The test item was semi-solid at ambient temperature; therefore it was necessary to heat it up to 90°C.

Results and discussion

Flash point
Flash point:
>= 141.2 - <= 143.2 °C
Atm. press.:
ca. 760 mm Hg

Applicant's summary and conclusion

Conclusions:
The determination of the flash point was carried out according to the Pensky-Martens closed cup method (non-equilibration method). The observed flash points were 141.2 and 143.2. The mean value of the corrected flash points of the two single runs is 142.2°C.