Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19 Jun 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC method 187 (particle size analysis by laser diffraction)
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
1.65 µm
St. dev.:
0.57
Key result
Percentile:
D50
Mean:
10.3 µm
St. dev.:
0.15
Percentile:
D90
Mean:
32.1 µm
St. dev.:
2.47

RESULTS

Table 1 Measurements

Median (µm) d10 (µm) d90 (µm)
1 10.940 1.621 34.208
2 10.429 1.622 33.848
3 9.501 1.521 28.351
4 9.899 1.566 30.868
5 10.567 1.916 33.296
Average 10.3 1.65 32.1
Conclusions:
The average particle size results are Dv(10) 1.65 µm, Dv(50) 10.3 µm and Dv(90) 32.1 µm.
Executive summary:

The particle size distribution of the test substance was determined using laser diffraction in accordance with CIPAC method 187 and GLP principles. The average particle size results are Dv(10) 1.65 µm, Dv(50) 10.3 µm and Dv(90) 32.1 µm.

Description of key information

Particle sizes: Dv(10) 1.65 µm, Dv(50) 10.3 µm and Dv(90) 32.1 µm, CIPAC method 187, particle size analysis by laser diffraction, Das 2008

Additional information