Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17th December 2018 - 21st December 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
Version / remarks:
Adopted 29 July 2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: EC Guideline No. 440/2008. Part B: Methods for the Determination of Toxicity and other health effects, Guideline B.40 BIS: "In Vitro Skin Corrosion: Human Skin Model Test".
Version / remarks:
Official Journal of the European Union No. L142, 31 May 2008.
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
1-(heptyloxy)-4-{2-[4-(heptyloxy)phenyl]-4-methylpentan-2-yl}benzene
EC Number:
830-582-9
Cas Number:
1951440-04-2
Molecular formula:
C32H50O2
IUPAC Name:
1-(heptyloxy)-4-{2-[4-(heptyloxy)phenyl]-4-methylpentan-2-yl}benzene
Test material form:
liquid: viscous
Specific details on test material used for the study:
Batch (Lot) Number: AS455433
Expiry date: 01 November 2020 (retest date)
Physical Description: Colourless to light yellow viscous liquid
Purity/Composition: 98.5%
Storage Conditions: At room temperature protected from light

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Justification for test system used:
Recommended test system in international guidelines (OECD and EC).
Vehicle:
unchanged (no vehicle)
Details on test system:
Test system:

EpiDerm Skin Model (EPI-200, Lot no.: 29674 Kit K and L, Appendix 4).
The model consists of normal, human-derived epidermal keratinocytes which have been cultured to form a multilayered, highly differentiated model of the human epidermis.
It consists of organized basal, spinous and granular layers, and a multi-layered stratum corneum containing intercellular lamellar lipid layers arranged in patterns analogous to those found in vivo. The EpiDerm tissues (surface 0.6 cm²) were cultured on polycarbonate membranes of 10 mm cell culture inserts.

Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
Excessive amount of the undiluted substance
50 µL Milli-Q water (negative control)
50 µL 8N KOH (positive control)
Duration of treatment / exposure:
3 minutes and 1 hour
Duration of post-treatment incubation (if applicable):
3 hours (incubation with MTT).
Number of replicates:
Substance and controls: 2 for each time point

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
3 minutes
Value:
95
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
1 hour
Value:
102
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Other effects / acceptance of results:
The absolute mean OD570 (optical density at 570 nm) of the negative control tissues was within the acceptance limits of OECD 431 (lower acceptance limit ≥0.8 and upper acceptance limit equal to or lower than 2.8) and the laboratory historical control data range. The mean relative tissue viability following the 1-hour exposure to the positive control was 6.6%.

Any other information on results incl. tables

Mean Absorption in the in vitro Skin Corrosion Test with the Substance.

 

 3 -minute application viability (%)

   1 -hour application viability (%)

A (OD570)

B (OD570)

Mean (OD570)

SD (+/-)

A (OD570)

B (OD570)

Mean (OD570)

SD (+/-)

Negative control

1.825

1.732

1.779

0.066

1.736

1.620

1.678

0.083

Substance

1.643

1.733

1.688

0.064

1.670

1.739

1.704

0.049

Positive control

0.102

0.124

0.113

0.015

0.108

0.112

0.110

0.003

SD = Standard deviation

Duplicate exposures are indicated by A and B.

In this table the values are corrected for background absorption (0.0424). Isopropanol was used to measure the background absorption.

Mean Tissue Viability in the in vitro Skin Corrosion Test with the Substance.


 

3-minute application viability (% of control)

1-hour application viability (% of control)

Negative control

100

100

Substance

95

102

Positive control

6.3

6.6

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The substance is considered to be non-corrosive to skin based on a reliable in vitro skin corrosion study.
Executive summary:

In a reliable in vitro skin corrosion study, conducted according to the OECD Guideline 431, 'In Vitro Skin Corrosion: reconstructed human epidermis (RHE) test method', the undiluted substance (50 µL) was applied onto reconstructed human skin tissue (epidermal model, EpiDerm (EPI-200)) in duplicate for a period of 3 or 60 minutes.

Skin corrosion is expressed as the remaining cell viability after exposure to the substance. The relative mean tissue viability obtained after 3-minute and 1-hour treatments with the substance compared to the negative control tissues was 95% and 102%, respectively. Because the mean relative tissue viability for the substance was not below 50% after the 3-minute treatment and not below 15% after the 1-hour treatment the substance is considered to be not corrosive.

In conclusion, the substance is not corrosive in the in vitro skin corrosion test under the experimental conditions described in this study.