Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20 Mar 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Remarks:
Laser diffraction but no guideline followed
Qualifier:
no guideline followed
Principles of method if other than guideline:
Laser diffraction method
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
261.2 µm
Remarks on result:
other: St dev not determined
Percentile:
D50
Mean:
391 µm
Remarks on result:
other: St dev not determined
Percentile:
D90
Mean:
552.5 µm
Remarks on result:
other: St dev not determined

Summarized data Values

MV (μm) 402.1

MN (μm) 293.4

MA (μm) 366.5

CS 0.01637

SD (μm) 111.7

Peak (μm) 391.0
Frequency (%) 100.00
Width (μm) 223.4

Results

Cumulative [%]

Particle Size [µm]

10

261.2

20

303.9

30

335.7

40

363.8

50

391.0

60

419.4

70

452.0

80

492.0

90

552.5

95

609.1

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
8 Nov - 21 Nov 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Remarks:
Japanese Industrial Standard
Qualifier:
according to guideline
Guideline:
other: JIS-K0069
Type of method:
sieving
Type of particle tested:
aggregate
Type of distribution:
mass based distribution
No.:
#1
Size:
>= 0 - <= 150 µm
Distribution:
6 %
No.:
#2
Size:
>= 150 - <= 180 µm
Distribution:
0.4 %
No.:
#3
Size:
>= 180 - <= 250 µm
Distribution:
11.5 %
No.:
#4
Size:
>= 250 - <= 300 µm
Distribution:
13.6 %
No.:
#5
Size:
>= 300 - <= 355 µm
Distribution:
13.5 %
No.:
#6
Size:
>= 355 - <= 425 µm
Distribution:
21.8 %
No.:
#7
Size:
>= 425 - <= 500 µm
Distribution:
18.7 %
No.:
#8
Size:
>= 500 - <= 710 µm
Distribution:
12.8 %
No.:
#9
Size:
>= 710 - <= 1 000 µm
Distribution:
1.7 %
No.:
#10
Size:
>= 1 000
Distribution:
0 %

Description of key information

D10: 261.2 µm

D50: 391.0 µm

D90: 552.5 µm

(Laser diffraction method)

Additional information