Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 276-851-9 | CAS number: 72797-41-2
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Particle size distribution (Granulometry)
Administrative data
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- August to november 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Justification for type of information:
- The determination was carried out using a procedure designed to be compatible with European Commission Guidance Document EUR 20268 ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’ (2002).
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 018
- Report date:
- 2018
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- other: according to Guidance Document EUR 20268
- Version / remarks:
- ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Sub
stances’ (2002). - Deviations:
- no
- Principles of method if other than guideline:
- Sieve Screening Test followed by Cascade Impactor :
First screening test : The sieve shaker table, on which the sieve rests, had an inclination of 4.5°, a nominal rotation speed of 2.5 rpm and vibrated at approximately 300 oscillations/min with an approximately 4 mm amplitude. Following the shaking period, the mass of the receiver pan and collected test
item was recorded and the percentage of test item with a particle size less than 100 μm calculated.
Second part, cascade impactor : A Particles larger than the cut size of a stage, impact onto the collection plate and stay in the collection cup. Smaller particles follow the airstream and are carried to the next stage. In succeeding stages the nozzles are smaller, the air velocity is higher and finer particles are collected. In the final stage the smallest particles are collected on a glass fibre filter. The mass of the artificial throat, collection cups and filter were recorded before and after each determination. air flow enters the impactor through a throat and inlet tube and then accelerates through the multiple stages. At each stage one or more nozzles direct the particle-laden airstream into a collection cup. - GLP compliance:
- yes (incl. QA statement)
- Type of method:
- cascade impaction
- Type of particle tested:
- primary particle
- Type of distribution:
- mass based distribution
Test material
- Reference substance name:
- (±)-7-[(3-chloro-6,11-dihydro-6-methyldibenzo[c,f][1,2]thiazepin-11-yl)amino]heptanoic acid S,S-dioxide
- EC Number:
- 276-851-9
- EC Name:
- (±)-7-[(3-chloro-6,11-dihydro-6-methyldibenzo[c,f][1,2]thiazepin-11-yl)amino]heptanoic acid S,S-dioxide
- Cas Number:
- 72797-41-2
- Molecular formula:
- C21H25ClN2O4S
- IUPAC Name:
- (±)-7-[(3-chloro-6,11-dihydro-6-methyldibenzo[c,f][1,2]thiazepin-11-yl)amino]heptanoic acid S,S-dioxide
- Test material form:
- solid: crystalline
- Details on test material:
- White powder
Constituent 1
- Specific details on test material used for the study:
- Batch18114773 - purity > 99.5%
Sieving Apparatus (Screening Test)
Instrument : Inclyno Sieve Shaker, Model No 1
Sieve : 100 μm stainless steel mesh (ISO 3310-1: 2000)
Cascade Impactor Instrument :
MSP Corporation, Marple Miller 160 Cascade Impactor
Particle size range : nominally 0.3 to 10 μm
Results and discussion
Particle size distribution at different passagesopen allclose all
- No.:
- #1
- Size:
- < 100 µm
- Distribution:
- ca. 33 %
- No.:
- #2
- Size:
- < 10 µm
- Distribution:
- ca. 0.27 %
- No.:
- #3
- Size:
- < 5.5 µm
- Distribution:
- ca. 0.14 %
Any other information on results incl. tables
The results of the sieving procedure are :
Mass of test item transferred to sieve : 11.44 g
Mass of test item passed through sieve : 3.77 g
Percentage of test item less than 100 μm : 33.0 %
The results of the cascade impactor procedure are shown in the joint document YS59RN
Applicant's summary and conclusion
- Conclusions:
- Sampling for the cascade impactor determinations was performed by rolling the test item container for approximately 10 minutes then sampled from the top, middle and bottom.
The overall results from the cascade impactor were taken as limit values due to the variation between the sampling positions; this gives a worst case scenario.
Too few particles were of a size less than 10.0 μm to allow accurate assessment of the mass median aerodynamic diameter.
The inhalable fraction is defined as the mass fraction of particles which can be inhaled by nose or mouth, the thoracic fraction is defined as the mass fraction of particles that passes the larynx and the respirable fraction is defined as the mass fraction of particles that reaches the alveoli.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.