Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 915-610-0 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 10 Apr 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 017
- Report date:
- 2017
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 438 (Isolated Chicken Eye Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
- Version / remarks:
- adopted 26 Jul 2013
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Medicines & Healthcare products Regulatory Agency, UK
Test material
- Reference substance name:
- Reaction mass of 1,2,3,4,4a,5,6,7-octahydro-2,5,5-trimethyl-2-naphthol and 4-(2,6,6-trimethyl-2-cyclohexen-1-yl)butan-2-one
- EC Number:
- 915-610-0
- Molecular formula:
- C13H2O
- IUPAC Name:
- Reaction mass of 1,2,3,4,4a,5,6,7-octahydro-2,5,5-trimethyl-2-naphthol and 4-(2,6,6-trimethyl-2-cyclohexen-1-yl)butan-2-one
Constituent 1
Test animals / tissue source
- Species:
- chicken
- Strain:
- not specified
- Details on test animals or tissues and environmental conditions:
- SOURCE OF COLLECTED EYES
- Source: Baileys Turkeys Ltd., Cheshire, UK
- Characteristics of donor animals: Chickens were approx. 56 days old and weighed 3 kg prior to slaughter.
- Storage, temperature and transport conditions of ocular tissue: Following slaughter, the intact chicken heads were placed into individual plastic compartments within a plastic box in order to minimize any damage to the eyes. The base of each compartment was lined with a paper towel moistened with isotonic saline. The heads were transported to the test facility at ambient temperature.
- Time interval prior to initiating testing: Heads were removed immediately after the chickens had been humanely killed at the source, for use on the same day. The time interval between collection of chicken heads and placing the eyes in the superfusion chamber following enucleation was minimized although all eyes had to fall within the acceptance criteria identified in the test guideline.
- Indication of any existing defects or lesions in ocular tissue samples: no
- Indication of any antibiotics used: no
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL
- Amount applied: 30 µL - Duration of treatment / exposure:
- 10 sec
- Duration of post- treatment incubation (in vitro):
- 240 min
Reading time points: 30, 75, 120, 180 and 240 min (± 5 min) - Number of animals or in vitro replicates:
- 3 eyes for test group and positive control; 2 eyes for negative control
- Details on study design:
- SELECTION AND PREPARATION OF ISOLATED EYES
The integrity of the cornea was measured with a microscope after instillation of sodium fluorescein (2%, w/v). Acceptable values for fluorescein retention and corneal opacity scores are ≤ 0.5. Eyes acceptable for testing were dissected from the skull and pulled from the orbit by holding the nictitating membrane firmly with surgical forceps. The tissue behind the eye was carefully removed with bent, blunt-tipped scissors.
Once the eye was removed from the orbit a portion of the optic nerve remained. Other connective tissue was removed from the eye on an absorbent tray liner. Enucleated eyes were transferred to an appropriate clamp keeping the cornea vertical. They were then transferred to chambers within the superfusion apparatus ensuring the corneas received sufficient isotonic saline from the saline drip. The temperature of the chambers was at 32 ± 1.5 °C.
Once all eyes were placed in the superfusion apparatus, the eyes were examined again for corneal damage with the microscope. Corneal thickness measurements are taken with a depth measuring device on a microscope at the center of each cornea.
Eyes were replaced when: (i) the fluorescein score was > 0.5; (ii) the corneal opacity score was > 0.5; or (iii) there was any additional signs of damage, (iv) the corneal thickness measurements for individual eyes deviated more than 10% from the mean value for all eyes.
EQUILIBRATION AND BASELINE RECORDINGS
After the approval process the eyes were incubated for 45 min for equilibrium purposes. Time zero measurements for corneal thickness and opacity were taken to serve as a baseline. The baseline for the fluorescein measurements were taken at dissection.
REMOVAL OF TEST SUBSTANCE
- Volume and washing procedure after exposure period: The test item was then rinsed from the eye using 20 mL of isotonic saline.
METHODS FOR MEASURED ENDPOINTS:
- Corneal opacity: Haag-Streit BQ 900 slit-lamp microscope
- Damage to epithelium based on fluorescein retention: Haag-Streit BQ 900 slit-lamp microscope
- Swelling: Corneal thickness was measured with a depth measuring device no. 1 on a slit-lamp microscope.
- Macroscopic morphological damage to the surface: Haag-Streit BQ 900 slit-lamp microscope
SCORING SYSTEM:
- Mean corneal swelling (%) : Percentage corneal swelling was assessed from corneal thickness measurements. The calculation was expressed in the following formula:
(corneal thickness at time (t) - corneal thickness at time =0) / (corneal thickness at time =0) x 100
Mean percentage of corneal swelling for all test eyes was calculated for all the time points. The overall category score was determined from the highest mean score for epithelial swelling as observed at any time point.
- Mean maximum opacity score :
Corneal opacity was calculated with the most densely opacified areas for scoring. The mean value for all test eyes was calculated for all time points. The highest mean score, as observed at any time point was given an overall category for each test item.
Opacity scores:
0 = No opacity
0.5 = Very faint opacity
1 = Scattered or diffuse areas; details of the iris are clearly visible
2 = Easily discernible translucent area; details of the iris are slightly obscured
3 = Severe corneal opacity; no specific details of the iris are visible; size of the pupil barely discernible
4 = Complete corneal opacity; iris invisible
- Mean fluorescein retention score at 30 minutes post-treatment :
The mean fluorescein retention scores for all test eyes are calculated at the 30 minute time interval only. These measurements are used for the overall classification for each test item.
Fluorescein retention scores:
0 = No fluorescein retention
0.5 = Very minor single cell staining
1 = Single cell staining scattered throughout the treated area of the cornea
2 = Focal or confluent dense single cell staining
3 = Confluent large areas of the cornea retaining fluorescein
DECISION CRITERIA:
ICE classification criteria as explained in OECD TG 438 were used.
Results and discussion
In vitro
Resultsopen allclose all
- Irritation parameter:
- cornea opacity score
- Run / experiment:
- 240 min
- Value:
- 1
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- other: ICE Class II
- Irritation parameter:
- fluorescein retention score
- Run / experiment:
- 30 min
- Value:
- 0.7
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- other: ICE Class II
- Irritation parameter:
- percent corneal swelling
- Run / experiment:
- 240 min
- Value:
- 12.44
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- other: ICE Class II
- Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: Not specified
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: Yes, No fluorescein retention was noted in both negative control treated eyes.
- Acceptance criteria met for positive control: Yes, Confluent large areas of the cornea retaining fluorescein were noted in all positive control treated eyes.
Any other information on results incl. tables
Table 2: Ocular reactions in observed eyes
|
Score |
ICE class |
Test item |
|
|
Maximal mean score for corneal opacity |
1.0 |
II |
Mean score of fluorescein retention |
0.7 |
II |
Maximan mean corneal swelling |
12.44% |
II |
Positive control |
|
|
Maximal mean score for corneal opacity |
4.0 |
IV |
Mean score of fluorescein retention |
3.0 |
IV |
Maximan mean corneal swelling |
47.57% |
IV |
Negative control |
|
|
Maximal mean score for corneal opacity |
0.3 |
I |
Mean score of fluorescein retention |
0.0 |
I |
Maximan mean corneal swelling |
0.00% |
I |
Applicant's summary and conclusion
- Interpretation of results:
- other: non-corrosive according to OECD 438
- Conclusions:
- The irritation potential of the test substance was assessed in the ICE assay. After treatment with the neat test substance corneal opacity, fluorescein retention and corneal swelling were all classed as category II. According to OECD 438 the test substance does not have to be classified as corrosive to the eye but no prediction on the eye irritation potential can be made and further testing is required for classification and labeling purposes.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.