Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
ISO No., other: Penskey Martens Apparatus
Principles of method if other than guideline:
The flash point determination of test chemical was done following closed cup method using Pensky-Martens flash point apparatus.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
189.6 °C
Atm. press.:
979 hPa
Remarks on result:
other: No other detail available
Interpretation of results:
other: non flammable
Conclusions:
The flash point determination of test chemical was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 189.6°C at 979.0hPa.
Executive summary:

The flash point determination of test chemical was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 189.6°C at 979.0hPa.

Description of key information

The flash point determination of test chemicalwas done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 189.6°C at 979.0hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
189.6 °C

Additional information

The flash point determination of test chemicalwas done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 189.6°C at 979.0hPa.

From the other authoritative databases Flash point value of test chemical was estimated to be 213.9±15.8 °C