Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Specific details on test material used for the study:
Substance ID: DPX-JE874
Purity: 97.0%
Batch: JEGX150808
Key result
Percentile:
other: d(0.1)
Mean:
8 µm
Remarks on result:
other: diameter where 90% of the distribution is above and 10% is below
Key result
Percentile:
other: d(0.5)
Mean:
21 µm
Remarks on result:
other: diameter where 50% of the distribution is above and 50% is below. The is referred to as the Mass Median Diameter (MMD)
Key result
Percentile:
other: d(0.9)
Mean:
110 µm
Remarks on result:
other: diameter where 10% of the distribution is above and 90% is below
Conclusions:
The test substance was determined to have d(0.1), d(0.5) and d(0.9) values of 8, 21 and 110 μm, respectively.
Executive summary:

A study was conducted to determine the particle size distribution of the test substance.


The study was conducted in accordance with guidelines to meet the requirements of Commission Regulation (EU) No 283/2013 of 01 March 2013 implementing Regulation No 1107/2009; and the US Environmental Protection Agency, Office of Chemical Safety and Pollution Prevention (OCSPP), Series 830: Product Properties Test Guidelines.


The particle size distribution was assessed using a technique based on laser diffraction in accordance with CIPAC MT 187.


The test substance was determined to have d(0.1), d(0.5) and d(0.9) values of 8, 21 and 110 μm, respectively.


d(0.1) is the diameter where 90% of the distribution is above and 10% is below.


d(0.5) is the diameter where 50% of the distribution is above and 50% is below. The is referred to as the Mass Median Diameter (MMD).


d(0.9) is the diameter where 10% of the distribution is above and 90% is below.

Description of key information

ISO 13320; CIPAC MT 187

Additional information

d(0.1), d(0.5) and d(0.9) values are 8, 21 and 110 μm