Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 700-426-3 | CAS number: 502962-81-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Particle size distribution (Granulometry)
Administrative data
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 04 March 2010 to 16 March 2010
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results. The study report was conclusive, done to a valid guideline and the study was conducted under GLP conditions.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 010
- Report date:
- 2010
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
- Version / remarks:
- guideline followed
- Deviations:
- no
- Principles of method if other than guideline:
- guideline followed
- GLP compliance:
- yes (incl. QA statement)
- Type of distribution:
- other:
Test material
- Reference substance name:
- LiTOFA
- IUPAC Name:
- LiTOFA
- Details on test material:
- Sponsor's identification: LiTOFA
Description: off white solid
Batch number: SF 173
Expiry date: 21 January 2012
Date received: 21 January 2010
Storage conditions: room temperature in the dark
Constituent 1
Results and discussion
Particle sizeopen allclose all
- Percentile:
- D50
- Mean:
- other:
- Remarks on result:
- other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
- Mean:
- other:
- Remarks on result:
- other: Not applicable
Particle size distribution at different passagesopen allclose all
- No.:
- #1
- Size:
- < 100 other: µm
- Distribution:
- 17.4 %
- No.:
- #2
- Size:
- < 10 other: µm
- Distribution:
- 0.127 %
- No.:
- #3
- Size:
- < 5.5 other: µm
- Distribution:
- 0.043 %
Any other information on results incl. tables
Results
Screening test (sieve method)
The results of the sieving procedure are shown in the following table:
Measurement |
Result |
Mass of test item transferred to sieve |
12.33 g |
Mass of test item passed through sieve |
2.14 g |
Proportion of test item <100 µm |
17.4 % |
Definitive test (cascade impactor method)
The results of the cascade impactor method determinations are shown as follows:
Determination1
Collection Stage |
ParticleCollected (µm) |
Masses (g) |
||
Pre-sampling |
Post-sampling |
Difference |
||
Cup 1 |
>10.0 |
86.1248 |
89.0081 |
2.8833 |
Cup 2 |
5.5 to 10.0 |
85.6309 |
85.6309 |
0.0000 |
Cup 3 |
2.4 to 5.5 |
86.0722 |
86.0724 |
0.0002 |
Cup 4 |
1.61 to 2.4 |
85.7852 |
85.7853 |
0.0001 |
Cup 5 |
0.307 to 1.61 |
85.9348 |
85.9342 |
-0.0006 |
Filter |
<0.307 |
75.6477 |
75.6478 |
0.0001 |
Mass of test item found in artificial
throat: 0.20 g
Total mass of test item recovered from artificial throat, sample cups
and filter:
3.0831 g
Determination 2
Collection Stage |
ParticleCollected (µm) |
Masses (g) |
||
Pre-sampling |
Post-sampling |
Difference |
||
Cup 1 |
>10.0 |
86.1245 |
87.0634 |
0.9398 |
Cup 2 |
5.5 to 10.0 |
85.6303 |
85.6344 |
0.0041 |
Cup 3 |
2.4 to 5.5 |
86.0723 |
86.0721 |
-0.0002 |
Cup 4 |
1.61 to 2.4 |
85.7847 |
85.7841 |
-0.0006 |
Cup 5 |
0.307 to 1.61 |
85.9348 |
85.9340 |
-0.0008 |
Filter |
<0.307 |
75.6464 |
75.6453 |
-0.0011 |
Mass of test item found in artificial
throat: 2.29 g
Total mass of test item recovered from artificial throat, sample cups
and filter:
3.2303 g
Determination 3
Collection Stage |
ParticleCollected (µm) |
Masses (g) |
||
Pre-sampling |
Post-sampling |
Difference |
||
Cup 1 |
>10.0 |
86.1249 |
88.0235 |
1.8986 |
Cup 2 |
5.5 to 10.0 |
85.6301 |
85.6305 |
0.0004 |
Cup 3 |
2.4 to 5.5 |
86.0720 |
86.0713 |
-0.0007 |
Cup 4 |
1.61 to 2.4 |
85.7849 |
85.7841 |
-0.0008 |
Cup 5 |
0.307 to 1.61 |
85.9339 |
85.9336 |
-0.0003 |
Filter |
<0.307 |
75.6468 |
75.6481 |
0.0013 |
Mass of test item found in artificial
throat: 1.11 g.
Total mass of test item recovered from artificial throat, sample cups
and filter:
3.0085 g.
Cumulative amounts
The cumulative amounts of test item found in the three determinations for the individual particle size cut-points (µm) are shown in the following table:
Particle Size Cut-point (µm) |
*Cumulative Mass (g) |
*Cumulative Percentage (%) |
||||
Determination 1 |
Determination 2 |
Determination 3 |
Determination 1 |
Determination 2 |
Determination 3 |
|
10.0 |
0.0004 |
0.0041 |
0.0017 |
1.30 x 10-2 |
0.127 |
5.65 x 10-2 |
5.5 |
0.0004 |
0.0000 |
0.0013 |
1.30 x 10-2 |
none detected |
4.321 x 10-2 |
2.4 |
0.0002 |
0.0000 |
0.0013 |
6.49 x 10-3 |
none detected |
4.321 x 10-2 |
1.61 |
0.0001 |
0.0000 |
0.0013 |
3.24 x 10-3 |
none detected |
4.321 x 10-2 |
0.307 |
0.0001 |
0.0000 |
0.0013 |
3.24 x 10-3 |
none detected |
4.321 x 10-2 |
*Where the post-sampling weight is greater than the pre-sampling weight resulting in a negative difference value (see tables 7.3, 7.4 and 7.5), a difference value of 0 has been used to calculate the cumulative mass and cumulative percentage.
The overall cumulative percentage (%) of test item with a particle size less than 10.0 µm and 5.5 µm (%) are shown in the following table:
Particle size |
Cumulative Percentage (%) |
||
Determination 1 |
Determination 2 |
Determination 3 |
|
<10.0 µm |
1.30 x 10-2 |
0.127 |
5.65 x 10-2 |
<5.5 µm |
1.30 x 10-2 |
None detected |
4.321 x 10-2 |
Applicant's summary and conclusion
- Conclusions:
- Conclusion
Particle size data acquired for the test item is shown in the following table:
Measurement Method Result
Proportion of test item having an inhalable particle size <100 µm Sieve 17.4 %
Proportion of test item having a thoracic particle size <10.0 µm Cascade Impactor 0.127 %
Proportion of test item having a respirable particle size <5.5 µm Cascade Impactor 4.321 x 10-2% - Executive summary:
Particle size data has been acquired using a procedure designed to comply with the European Commission technical guidance document 'Particle Size Distribution, Fibre Length and Diater Distribution' (June 1996), which satisfies the requirents of OECD Guideline 110. The results are as follows:
Measurement
Method
Result
Proportion of test item having an inhalable particle size less than 100 µm
Sieve
17.4%
Proportion of test item having a thoracic particle size less than 10.0 µm
Cascade Impactor
0.127%
Proportion of test item having a respirable particle size less than 5.5 µm
Cascade Impactor
4.321 x 10-2%
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.