EC number: 619-409-6 | CAS number: 99208-50-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- June 17, 2019
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Justification for type of information:
- Required by REACH
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 019
- Report date:
- 2019
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
- Version / remarks:
- October 9, 2017
- Deviations:
- yes
- Remarks:
- The positive control is 10% (w/v) Benzalkonium chloride (purity not indicated by the producer) in saline since the laboratory historical control data is established with this chemical.
- Qualifier:
- according to guideline
- Guideline:
- EU method B.47 (Bovine corneal opacity and permeability test method for identifying ocular corrosives and severe irritants)
- Version / remarks:
- 9.12.2010
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: Bovine Corneal Opacity and Permeability (BCOP) Assay, SOP of Microbiological Associates Ltd., UK, Procedure Details, April 1997.
- Version / remarks:
- April 1997
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: Commission Regulation (EU) No 2017/735 amending, for the purpose of its adaptation to technical progress, the Annex to Regulation (EC) No 440/2008 laying down test methods pursuant to Regulation (EC) No 1907/2006 (Reach).
- Version / remarks:
- 2017
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- 9-(2,5-dihydroxyphenyl)-8-oxa-9λ⁵-phosphatricyclo[8.4.0.0²,⁷]tetradeca-1(14),2,4,6,10,12-hexaen-9-one
- EC Number:
- 619-409-6
- Cas Number:
- 99208-50-1
- Molecular formula:
- C18H13O4P
- IUPAC Name:
- 9-(2,5-dihydroxyphenyl)-8-oxa-9λ⁵-phosphatricyclo[8.4.0.0²,⁷]tetradeca-1(14),2,4,6,10,12-hexaen-9-one
- Test material form:
- solid: particulate/powder
Constituent 1
- Specific details on test material used for the study:
- Purity: 99.7%
Physical description: white powder
Storage conditions: room temperature
Expiration date: March 20, 2020
Test animals / tissue source
- Species:
- cattle
- Details on test animals or tissues and environmental conditions:
- Collection of Bovine Eyes
Freshly isolated bovine eyes of donor cattle were collected from the abattoir. Excess tissue was removed from the excised eyes. The isolated eyes were stored in HBSS (Hank’s Buffered Salt Solution) containing 1% (v/v) penicillin/streptomycin (100 units/mL penicillin and 100 μg/mL streptomycin) in the cooled slaughter-house and during transportation on the same morning to the laboratory using a Styrofoam box. The corneae were isolated on the same day after delivery of the eyes.
Preparation of Corneae
All eyes were carefully examined macroscopically for defects. Those presenting defects such as vascularization, pigmentation, opacity and scratches were discarded. The cornea was carefully removed from the eye using scalpel and rounded scissors. A rim of about 2 mm of tissue (sclera) was left for stability and handling of the isolated cornea. The corneae were directly used in the BCOP test on the same day.
Each isolated cornea was mounted in a specially designed cornea holder according to the description given in OECD guideline 437, which consists of anterior and posterior compartments, which interface with the epithelial and the endothelial sides of the cornea, respectively. The endothelial side of the cornea was positioned against the sealing ring (O-ring) of the posterior part of the holder. The cornea was gently flattened over the O-ring but stretching was avoided. The anterior part of the holder was positioned on top of the cornea and fixed in place with screws. Both compartments of the holder were filled with incubation medium. The posterior compartment was filled first to return the cornea to its natural convex position. Care was taken to assure that no air bubbles were present within the compartments.
For equilibration, the corneae in the holder were incubated in a vertical position for about one hour at 32 ± 1 °C in a water-bath. At the end of the incubation period, the medium was changed before basal opacity measurement (t0).
At the end of the incubation period, the basal opacity was determined (t0).
Only corneae with a value of the basal opacity < 7 were used. Sets of three corneae were used for treatment with the test item and for the negative and positive controls, respectively.
Test system
- Vehicle:
- physiological saline
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- 20%
- Duration of treatment / exposure:
- 240 minutes
- Duration of post- treatment incubation (in vitro):
- Following to the opacity readings, the permeability endpoint was measured as an indication of the integrity of the epithelial cell sheets. After the final opacity measurement was performed, the incubation medium was removed from both chambers. The posterior chamber was filled with fresh cMEM first. Then the anterior compartment was filled with 1 mL of a 0.5% (w/v) sodium fluorescein solution in HBSS. Corneae were incubated again in a horizontal position for 90 ± 5 minutes in a water-bath at 32 ± 1 °C. Incubation medium from the posterior compartment was removed, well mixed and transferred into a 96 well plate.
The optical density was measured with a microplate reader (Versamax® Molecular Devices) at 490 nm (OD490). The absorbance values were determined using the software SoftMax Pro Enterprise (version 4.7.1). - Number of animals or in vitro replicates:
- 3
- Details on study design:
- This in vitro study was performed to assess the corneal irritation and damage potential of DOPO-HQ by means of the BCOP assay using fresh bovine corneae.
After a first opacity measurement of the fresh bovine corneae (t0), the 20% (w/v) suspension in saline (0.9% (w/v) NaCl in deionised water) of the test item DOPO-HQ as well as the positive and the negative controls were each applied to different corneae fixed in an incubation chamber in horizontal position and incubated for 240 minutes at 32 ± 1 °C. The posterior chamber contained incubation medium. After the incubation phase the test item, the positive, and the negative controls were each rinsed from the corneae and opacity was measured again (t240).
After the opacity measurements, permeability of the corneae was determined by measuring spectrophotometrically the transfer of sodium fluorescein after incubation in a horizontal position for 90 minutes at 32 ± 1 °C.
With the negative control (physiological saline), neither an increase of opacity nor permeability of the corneae was observed.
The positive control (10% (w/v) benzalkonium chloride in saline) showed clear opacity and distinctive permeability of the corneae corresponding to a classification as serious eye damage (EU CLP/UN GHS Category 1).
Relative to the negative control, the test item DOPO-HQ did not cause a relevant increase of the corneal opacity or permeability. The calculated mean in vitro irritancy score was 1.37. According to OECD 437 (see table in chapter 3.8.3) the test item is not categorized (EU CLP/UN GHS No Category).
Results and discussion
In vitro
Resultsopen allclose all
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- Negative control
- Value:
- >= 2.02
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- Negative control
- Value:
- >= 1.08
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- Negative control
- Value:
- >= 1.19
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- Positive control
- Value:
- >= 93.35
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- Positive control
- Value:
- >= 95.26
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- Positive control
- Value:
- >= 95.76
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- DOPO-HQ
- Value:
- >= 1.77
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- DOPO-HQ
- Value:
- >= 0.67
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- DOPO-HQ
- Value:
- >= 1.68
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- cornea opacity score
- Run / experiment:
- Negative control
- Value:
- >= 1
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- cornea opacity score
- Run / experiment:
- Negative control
- Value:
- >= 0
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- cornea opacity score
- Run / experiment:
- Positive control
- Value:
- >= 84.67
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- cornea opacity score
- Run / experiment:
- Positive control
- Value:
- >= 86.67
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- cornea opacity score
- Run / experiment:
- Positive control
- Value:
- >= 85.67
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- cornea opacity score
- Run / experiment:
- DOPO-HQ
- Value:
- >= 1.67
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- cornea opacity score
- Run / experiment:
- DOPO-HQ
- Value:
- >= 0.67
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- In conclusion, according to the current study and under the experimental conditions reported, DOPO-HQ is not categorized (EU CLP/UN GHS No Category).
- Executive summary:
This in vitro study was performed to assess the corneal irritation and damage potential of DOPO-HQ by means of the BCOP assay using fresh bovine corneae.
After a first opacity measurement of the fresh bovine corneae (t0), the 20% (w/v) suspension in saline (0.9% (w/v) NaCl in deionised water) of the test item DOPO-HQ as well as the positive and the negative controls were each applied to different corneae fixed in an incubation chamber in horizontal position and incubated for 240 minutes at 32 ± 1 °C. The posterior chamber contained incubation medium. After the incubation phase the test item, the positive, and the negative controls were each rinsed from the corneae and opacity was measured again (t240).
After the opacity measurements, permeability of the corneae was determined by measuring spectrophotometrically the transfer of sodium fluorescein after incubation in a horizontal position for 90 minutes at 32 ± 1 °C.
With the negative control (physiological saline), neither an increase of opacity nor permeability of the corneae was observed.
The positive control (10% (w/v) benzalkonium chloride in saline) showed clear opacity and distinctive permeability of the corneae corresponding to a classification as serious eye damage (EU CLP/UN GHS Category 1).
Relative to the negative control, the test item DOPO-HQ did not cause a relevant increase of the corneal opacity or permeability. The calculated mean in vitro irritancy score was 1.37. According to OECD 437 (see table in chapter 3.8.3) the test item is not categorized (EU CLP/UN GHS No Category).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.