Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02/06/2015 - 05/06/2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - Shake Flask Method)
Version / remarks:
Preliminary test
Deviations:
no
GLP compliance:
yes
Type of method:
estimation method (solubility ratio)
Partition coefficient type:
octanol-water

Test material

Constituent 1
Test material form:
solid: flakes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material:PREVOR, batch 040801#

Test item tested as received.

Study design

Analytical method:
other: the preliminary test result showed that no complementary test was possible (HPLC method cannot be used).

Results and discussion

Partition coefficient
Key result
Type:
log Pow
Partition coefficient:
-5
Remarks on result:
other: estimated value because the test item remained undissolved into octanol up to the concentration limit

Any other information on results incl. tables

Estimation of partition coefficient with the shake flask method:

 Solvent  Mass of sample (mg)  Solvent volume (ml)  Estimated solubility (g/l)  Log P
 Water  5002  5.011  998.20     -5.0
 Octanol  0.4  40  0.01

Octanol Sample Preparation: Approximately 2 mg of X300 was added to a 40 mL clear glass vial, followed by Octanol 40 mL. The sample was shaken, sonicated and warmed to approximately 40°C. The sample remained undissolved. The preparation above was repeated using 0.40 mg of X300. The second X300 sample remained undissolved. At concentrations below 10 mg/L it was difficult to accurately determine the presence X300. Therefore it is not known if the sample is soluble below this concentration or if this is the limit of detection for the visualisation of X300 in octanol.

Applicant's summary and conclusion

Conclusions:
The estimated partition coefficient Log Pow = -5
Executive summary:

The partition coefficient was estimated using the shake flask method according to the EU A.8 test guideline. The estimated value was: Log Pow = -5