Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20 November 2008 to 26 November 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
2004
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - Shake Flask Method)
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
Deviations:
no
GLP compliance:
yes
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
4.2
Temp.:
35 °C
Remarks on result:
other: pH not specified
Details on results:
- Linear regression parameters: log Pow = a * log k + b
- Correlation coefficient r = 0.9873 a= 2.8962 b = 2.7399

Table 1: Reference Substances

Reference Substance

log Pow

tR1

tr2

tRm

k

log k

Thiourea

-

2.219

2.216

2.22

-

-

Benzylalcohol

1.1

2.698

2.695

2.70

0.216

-0.666

Benzene

2.1

3.898

3.896

3.90

0.757

-0.121

Toluene

2.7

4.825

4.822

4.82

1.175

0.070

1,4-Dichlorobenzene

3.4

5.944

5.940

5.94

1.680

0.225

Cumene

3.7

7.130

7.126

7.13

2.214

0.345

1,2,4-Trichlorobenzene

4.2

8.852

8.848

8.85

2.991

0.476

Fluoranthene

5.1

14.611

14.606

14.61

5.588

0.747

tR1, tR2, tRm : retention times (1st measurement, 2nd measurement, average)

k = (tR/t0)-1 : capacity factor, t0 : "dead time", i.e. retention time of thiourea

Table 2: Test Material

 

tR1

tr2

tRm

k

log k

log Pow

Test Material

9.093

9.089

9.09

3.0997

0.4913

4.2

Conclusions:
Under the conditions of this study the log Pow of the test material was 4.2.
Executive summary:

The partition coefficient of the test material was investigated in accordance with the standardised guidelines OECD 117, EU Method A.8 and EPA OPPTS 830.7570, under GLP conditions, following the HPLC method.

The KOWWIN software tool provided by the U.S Environmental Protection Agency estimates the octanol/water partition coefficient of the test material to be 4.1. The OECD method 117 covers an octanol/water partition coefficient range from 0 to 6, and is therefore applicable for the test material.

The average retention time of the test material was 9.09 minutes, corresponding to a partition coefficient (log value) of 4.2.

Under the conditions of this study the log Pow of the test material was determined to be 4.2.

Description of key information

Under the conditions of the study the log Pow of the test material was 4.2.

Key value for chemical safety assessment

Log Kow (Log Pow):
4.2
at the temperature of:
35 °C

Additional information

The partition coefficient of the test material was investigated in accordance with the standardised guidelines OECD 117, EU Method A.8 and EPA OPPTS 830.7570, under GLP conditions, following the HPLC method. The study was awarded a reliability score of 1 in accordance with the criteria set forth by Klimisch et al. (1997).

The KOWWIN software tool provided by the U.S Environmental Protection Agency estimates the octanol/water partition coefficient of the test material to be 4.1. The OECD method 117 covers an octanol/water partition coefficient range from 0 to 6, and is therefore applicable for the test material.

The average retention time of the test material was 9.09 minutes, corresponding to a partition coefficient (log value) of 4.2.

Under the conditions of this study the log Pow of the test material was determined to be 4.2.