Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019.08.30
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source (i.e. manufacturer or supplier) and lot/batch number of test material:
Manufacturer: Ascend Performance Materials Inc.
Lot no.: 1205635
- Purity, including information on contaminants, isomers, etc.:
100%



STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material:
Ambient
- Stability and homogeneity of the test material in the vehicle/solvent under test conditions (e.g. in the exposure medium) and during storage:
stable
- Stability in the medium, i.e. sensitivity of the test material to hydrolysis and/or photolysis:
stable
- Solubility and stability of the test material in the solvent/vehicle and the exposure medium:
highly soluble
- Reactivity of the test material with the incubation material used (e.g. plastic ware):
non-reactive

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing (e.g. warming, grinding):
none
- Preliminary purification step (if any):
none
Flash point:
208 °C
Atm. press.:
1 atm
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of test substance at ambient atmosphere is 208℃, which is not classified as flammable liquid according to the GHS criteria.

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
208 °C

Additional information