Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2017-08-03 to 2018-03-09
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: European Commission Guidance Document EUR 20268 ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’ (2002).
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
cascade impaction
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
Specific details on test material used for the study:
- Appearance/Physical state: Pale brown powder
- Storage condition of test material: Room temperature, in the dark
- Expiry: 28 November 2018
No.:
#1
Size:
< 100 µm
Distribution:
98.3 %
Remarks on result:
other: Sieve method
No.:
#2
Size:
< 10 µm
Distribution:
0.34 %
Remarks on result:
other: Cascade Impactor
No.:
#3
Size:
< 5.5 µm
Distribution:
0.07 %
Remarks on result:
other: Cascade Impactor
Conclusions:
Percentage of test item with an inhalable particle size <100 μm : 98.3%
Percentage of test item with a thoracic particle size <10.0 μm : 0.34%
Percentage of test item with a respirable particle size <5.5 μm : 0.07%

Description of key information

Percentage of test item with an inhalable particle size <100 μm : 98.3%

Percentage of test item with a thoracic particle size <10.0 μm : 0.34%

Percentage of test item with a respirable particle size <5.5 μm : 0.07%

Additional information