EC number: 931-583-8 | CAS number: 66071-92-9
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
General information:
There are adequate first aid/medical facilities, trained personnel and equipment, including first aid response capabilities. The emergency eyewash and shower are inspected regularly. The provisions and procedures are under the company’s management system and also under authorities' surveillance.
The precautions in case of accident are:
Inhalation of gases:
- Provide fresh air, warmth and rest, preferably in comfortable upright sitting position. Get medical attention if any discomfort continues.
Skin contact:
- Remove immediately contaminated clothing and shoes. Rinse immediately with plenty of water. Contact physician.
Eye contact:
- Rinse immediately with plenty of water. Hold eyelids apart. Contact physician.
Ingestion:
- Rinse mouth with water. Drink a few glasses of water. Do not induce vomiting. Contact physician.
Fire-fighting measures
The material is combustible. Combustion gases may contain toxic sodium oxide (Na2O) vapours.
There are provisions and procedures in place for fire emergency situations under the company’s management system. There are appropriate fire fighting equipment including manual extinguishing equipment under management and authority surveillance and inspections (water, foam, dry chemicals or carbon dioxide). There are emergency evacuation procedures, training and fire drills are undertaken regularly. The full procedures and responsible persons are described in the emergency preparedness plan. The fire extinguishers are inspected regularly. There is cooperation and surveillance of the plant operations by the local fire department / corresponding authorities. Self contained breathing apparatus and a protection suit are required for fire fighting.
Accidental release measures
There are provisions and procedures in place for emergency situations that base on a risk assessment conducted to assess all known and potential hazards and under the Company’s management system.
During accidental situations procedures are in place to contain the intermediate within the process buildings / site. In case of accidental spillage, larger amounts should be absorbed and properly disposed of. Smaller spills may be diluted with water.
There are procedures in place also to inform people living in the surroundings and authorities of process disturbances and other special situations such as temporary process shut downs.
Environmental precautions:
- Small amounts can be rinsed with plenty of water. If a large amount has been released, start pumping waste water into the guard basin.
Methods for cleaning up:
- Rinse thoroughly with plenty of water.
Other precautions:
- Avoid reactions with acids. The substance liberates very toxic and flammable hydrogen sulphide (H2S) gas in contact with acids. pH lowering may cause release of acetic acid.
Handling and storage
The processes are closed. The intermediate is manufactured and consumed (turned into another substance) during its whole life cycle under strictly controlled conditions.
For loading and unloading, maintenance and emergency situations where limited exposure could potentially exist there are specific guidance and procedures, c.f. exposure controls / personal protection, Safety Data Sheets available for staff etc.
The staff is trained to a level pertinent to their post in all relevant operations of the plant and equipment at the site under the company’s management system.
There are specific provisions and procedures in place for certain tasks: hot work, working in ATEX premises, maintenance of pressurized equipment, working inside tanks, tunnels and pits, working in high places etc.
There are safety signs and labelling on chemical tanks and in certain areas.
The handling and storage of chemicals is under surveillance of authorities.
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- 3267
Shippingopen allclose all
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- 3267
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- 3267
Shipping information
- Proper shipping name and description:
- WOOD LIGNIN WITH SODIUM ACTETATE/OXLATE (Spent liquor form semi-chemical pulping)
- Chemical name:
- Spent liquor form semi-chemical pulping
- Labels:
- 8
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- 3267
Shipping information
- Proper shipping name and description:
- WOOD LIGNIN WITH SODIUM ACTETATE/OXLATE (Spent liquor from semi-chemical pulping)
- Chemical name:
- Spent liquor from semi-chemical pulping
- Labels:
- 8
Remarksopen allclose all
Additional transport information
Additional information
- Special provisions / remarks / other:
- Do not allow contacts with acids. pH lowering may cause release of acetic acid and hydrogen sulphide (H2S), which is a toxic and flammable gas.
Exposure controls / personal protection
The processes are closed. The intermediate is manufactured and consumed (turned into another substance) during its whole life cycle under strictly controlled conditions.
Exposure control elements in place include:
- Continuous monitoring of operations and processes, as well as environment automatically and by chemical and physical analysis and site inspections and walk through in operational premises.
- Emergency preparedness procedures, e.g. emergency preparedness plan under the company’s management system.
- Employee training procedures under the company’s management system.
- Employee health checks and other health care services.
- Surveillance of the company’s operations by authorities.
- Security and control, e.g. of access into the site.
Risk management measures implemented to minimise any exposure include:
- In case of handling substance Personal Protective Equipment (PPE) such as chemical resistant protective gloves and clothing and eye/face protection needs to be used and if necessary appropriate mask respirator with air.
- As the substance is corrosive, process equipment are checked regularly.
- Additionally good ventilation of working spaces is provided.
- Stationary hydrogen sulphide (H2S) measuring devices are installed in areas of H2S hazard.
- Measurement for hydrogen sulphide (H2S) is performed before work is conducted with equipments (tanks, etc.).
- Personal hydrogen sulphide (H2S) measuring devices is carried during work inside process equipment (e.g. during maintenance).
Stability and reactivity
The substance is stable at normal circumstances.
Contact with acids liberates toxic and flammable gas (hydrogen sulfide). pH lowering may cause release of acetic acid.
Disposal considerations
Under normal operation, no amount of the substance is generated that would require disposal considerations. If disposal is required, the substance is handled as dangerous waste.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.