Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1995-01-20 to 1995-01-30
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not measured/tested
Key result
Test series:
UN Test series 3
Method:
UN Test 3 (b) (i): BAM friction apparatus
Parameter:
other: Pin pressure 360 N
Result:
result is considered "-" (negative)
Remarks on result:
other: Six times negatice
Key result
Test series:
UN Test series 3
Method:
UN Test 3 (a) (ii): BAM Fallhammer
Parameter:
other: Mass 10 kg
Result:
result is considered "-" (negative)
Remarks on result:
other: Negative, no optical change in product apparent
Key result
Test series:
UN Test series 1
Method:
UN Test 1 (b): Koenen test
Parameter:
other: Nozzle Diameter 2 mm
Result:
result is considered "-" (negative)
Remarks on result:
other: No fragments, cartridge unchanged
Interpretation of results:
GHS criteria not met
Conclusions:
Test material is not explosive

Description of key information

Test material is not explosive, EU Method A.14, Mix H 1995.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification