Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 24 February 2012 to 27 March 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Key result
Boiling pt.:
> 600 °C
Atm. press.:
ca. 1 atm
Decomposition:
no

Assay No. 1:

Neither endothermic peak nor exothermic peak was recorded.

Assay No. 2:

An endothermic peak was observed at 69.8°C. This endothermic event reflected the fact that the rare earth salt solubilised in its hydration water. Indeed, the hydrated rare earth salts, such as the hydrated form of neodymium trinitrate, loose their water of hydration when heated. As these water molecules are loosely bound and as the amount of water in the substance is significant, the attached water is released and as a result the rare earth salt solubilizes in water. As a result, it is concluded that neodymium nitrate did not melt over the temperature range tested.

No other reaction was recorded up to 600°C.

Assays No. 3 and 4:

The assays No. 3 and 4 were not presented because they were performed in aluminium crucibles and the results were not exploitable. Then the other assays were performed in steel incoloy crucibles with crimped lid. As a result the test item appearance could not be observed after the DSC procedure.

Assay No. 5:

An endothermic peak was observed at 69.9°C. As for the second preliminary assay, this revealed the solubilisation of the rare earth salt in its hydration water.

Conclusions:
The DSC curve revealed an endothermic peak at 69.9 ± 0.5°C. This endothermic event reflected the fact that the rare earth salt solubilized in its hydration water. As a result, neodymium trinitrate did not melt over the temperature range tested.
No boiling point was recorded up to 600°C, under the experimental conditions tested.

Description of key information

The DSC curve revealed an endothermic peak at 69.9 ± 0.5°C. This endothermic event reflected the fact that the rare earth salt solubilized in its hydration water. As a result, neodymium trinitrate did not melt over the temperature range tested. No boiling point was recorded up to 600°C, under the experimental conditions tested. The boiling point is greater than 600°C.

Key value for chemical safety assessment

Additional information