Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Skin sensitisation
Administrative data
- Endpoint:
- skin sensitisation: in vivo (LLNA)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 10 February 2012 to 10 March 2012
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Study conducted to GLP in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 012
- Report date:
- 2012
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 429 (Skin Sensitisation: Local Lymph Node Assay)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.42 (Skin Sensitisation: Local Lymph Node Assay)
- Deviations:
- no
- Principles of method if other than guideline:
- There was an exception with regard to GLP: No analysis was carried out to determine the homogeneity, concentration or stability of the test item formulation. The test item was formulated within two hours of being applied to the test system; it is assumed that the formulation was stable for this duration. This exception is considered not to affect the purpose or integrity of the study.
- GLP compliance:
- yes (incl. QA statement)
- Type of study:
- mouse local lymph node assay (LLNA)
Test material
- Test material form:
- solid: particulate/powder
- Remarks:
- migrated information: powder
Constituent 1
In vivo test system
Test animals
- Species:
- mouse
- Strain:
- other: CBA/Ca
- Sex:
- female
- Details on test animals and environmental conditions:
- TEST ANIMALS
- Source: Harlan Laboratories UK Limited, Bicester, Oxon, UK
- Age at study initiation: 8 - 12 weeks old
- Weight at study initiation: 15 - 23 g
- Housing: individually housed in suspended solid-floor polypropylene cages furnished with softwood woodflakes
- Diet (e.g. ad libitum):2014C Teklad Global Rodent diet supplied by Harlan Laboratories UK Ltd., Oxon, UK ad libitum
- Water (e.g. ad libitum): mains tap water ad libitum
- Acclimation period: at least five days
The animals were provided with environmental enrichment items which were considered not to contain any contaminant of a level that might have affected the purpose or integrity of the study.
ENVIRONMENTAL CONDITIONS
- Temperature (°C): target range of 19 to 25°C
- Humidity (%): target range of 30 to 70%
Any occasional deviations from these targets were considered not to have affected the purpose or integrity of the study.
- Air changes (per hr): approximately fifteen changes per hour
- Photoperiod (hrs dark / hrs light): twelve hours continuous light (06.00 to 18.00) and twelve hours darkness
IN-LIFE DATES: From: 10 February 2012 - 8 March 2012
Study design: in vivo (LLNA)
- Vehicle:
- acetone/olive oil (4:1 v/v)
- Remarks:
- This vehicle was chosen as it produced the highest concentration that was suitable for dosing.
- Concentration:
- 10 %, 5 % and 2.5 % w/w in acetone/olive oil 4:1
- No. of animals per dose:
- 5
- Details on study design:
- PRELIMINARY SCREENING TEST
Using available information regarding the systemic toxicity of the test item, a preliminary screening test was performed using three mice, one mouse per test item concentration. The mice were treated by daily application of 25 µL of the test item at concentrations of 50 %, 25 % or 10 % w/w in acetone/olive oil 4:1, to the dorsal surface of each ear for three consecutive days (Days 1, 2, 3). The mice were observed twice daily on Days 1, 2 and 3 and once daily on Days 4, 5 and 6. Local irritation was scored daily and clinical signs of toxicity, if present, were also recorded. The bodyweight of each mouse was recorded on Day 1 (prior to dosing) and on Day 6.
MAIN TEST
Test Item Administration:
Groups of five mice were treated with the test item at concentrations of 10 %, 5 % or 2.5 % w/w in acetone/olive oil 4:1. The preliminary screening test suggested that the test item would not produce systemic toxicity or excessive local irritation at the highest suitable concentration. The mice were treated by daily application of 25 µL of the appropriate concentration of the test item to the dorsal surface of each ear for three consecutive days (Days 1, 2, 3). The test item formulation was administered using an automatic micropipette and spread over the dorsal surface of the ear using the tip of the pipette.
A further group of five mice received the vehicle alone in the same manner.
3H-Methyl Thymidine Administration:
Five days following the first topical application of the test item or vehicle (Day 6) all mice were injected via the tail vein with 250 µL of phosphate buffered saline (PBS) containing 3H-methyl thymidine (3HTdR:80µCi/mL, specific activity 2.0 Ci/mmol, ARC UK Ltd) giving a total of 20 µCi to each mouse.
Observations:
-Clinical Observations: All animals were observed twice daily on Days 1, 2 and 3 and on a daily basis on Days 4, 5 and 6. Any signs of toxicity or signs of ill health during the test were recorded.
-Bodyweights: The bodyweight of each mouse was recorded on Day 1 (prior to dosing) and Day 6 (prior to termination).
Terminal Procedures:
-Termination: Five hours following the administration of 3HTdR, all mice were killed by carbon dioxide asphyxiation followed by cervical separation. For each individual animal of each group the draining auricular lymph nodes were excised and processed. For each individual animal 1 mL of PBS was added to the lymph nodes.
-Preparation of Single Cell Suspension: A single cell suspension of the lymph node cells for each individual animal was prepared by gentle mechanical disaggregation through a 200-mesh stainless steel gauze. The lymph node cells were rinsed through the gauze with 4 mL of PBS into a petri dish. The lymph node cells suspension was transferred to a centrifuge tube. The petri dish was washed with an additional 5 mL of PBS to remove all remaining lymph node cells and these were added to the centrifuge tube. The lymph node cells were pelleted at 1400 rpm (approximately 190 x gravity) for ten minutes. The pellet was re-suspended in 10 mL of PBS and re-pelleted. To precipitate out the radioactive material, the pellet was re-suspended in 3 mL of 5 % Trichloroacetic acid (TCA).
-Determination of 3HTdR Incorporation: After approximately eighteen hours incubation at approximately 4 °C, the precipitates were recovered by centrifugation at 2100 rpm (approximately 450 x gravity) for ten minutes, re-suspended in 1 mL of TCA and transferred to 10 mL of scintillation fluid (Optiphase 'Trisafe'). 3HTdR incorporation was measured by β-scintillation counting. The "Poly Q" vials containing the samples and scintillation fluid were placed in the sample changer of the scintillator and left for approximately twenty minutes. The purpose of this period of time in darkness was to reduce the risk of luminescence, which has been shown to affect the reliability of the results. After approximately twenty minutes, the vials were shaken vigorously. The number of radioactive disintegrations per minute was then measured using the Beckman LS6500 scintillation system (Beckman Instruments Inc, Fullerton, CA, USA). - Positive control substance(s):
- hexyl cinnamic aldehyde (CAS No 101-86-0)
- Statistics:
- Statistical Analysis
Data was processed to give group mean values for disintegrations per minute and standard deviations where appropriate. Individual and group mean disintegrations per minute values were assessed for dose response relationships by analysis of homogeneity of variance followed by one way analysis of variance (ANOVA). In the event of a significant result from the ANOVA, pairwise comparisons were performed between control and treated groups. For homogenous datasets Dunnett's Multiple Comparison test was used and for non-homogenous datasets Dunnett's T3 Multiple Comparison Method was used.
Interpretation of Results
The proliferation response of lymph node cells was expressed as the number of radioactive disintegrations per minute per animal and as the ratio of 3HTdR incorporation into lymph node cells of test nodes relative to that recorded for the control nodes (Stimulation Index).
The test item will be regarded as a sensitiser if at least one concentration of the test item results in a threefold or greater increase in 3HTdR incorporation compared to control values. Any test item failing to produce a threefold or greater increase in 3HTdR incorporation will be classified as a "non-sensitiser".
The EC3 value was also calculated. The EC3 value is the concentration of test item expected to cause a 3 fold increase in 3HTdR incorporation. The equation used for the calculation of EC3 is:
EC3 = c + [[(3 - d) / (b - d)] x (a - c)]
Where a = lowest concentration giving stimulation index >3
b = actual stimulation index caused by a
c = highest concentration failing to produce a stimulation index of 3
d = actual stimulation index caused by c
Results and discussion
- Positive control results:
- Project number: 41103434
Study dates: 05 October 2011 - 11 October 2011
Methods. A group of five animals was treated with 50 µL (25 µL per ear) of α-Hexylcinnamaldehyde as a solution in acetone/olive oil 4:1 at a concentration of 25 % v/v. A further control group of five animals was treated with acetone/olive oil 4:1 alone.
Results. The Stimulation Index expressed as the mean radioactive incorporation for the treatment group divided by the mean radioactive incorporation of the vehicle control group is as follows:
Concentration (% v/v) in Stimulation Index Result
acetone/olive oil 4:1
25 4.05 Positive
Conclusion: α-Hexylcinnamaldehyde was considered to be a sensitiser under the conditions of the test.
In vivo (LLNA)
Resultsopen allclose all
- Key result
- Parameter:
- SI
- Value:
- 2.33
- Test group / Remarks:
- 2.5 %
- Key result
- Parameter:
- SI
- Value:
- 2.4
- Test group / Remarks:
- 5 %
- Key result
- Parameter:
- SI
- Value:
- 4.79
- Test group / Remarks:
- 10 %
- Parameter:
- other: disintegrations per minute (DPM)
- Remarks on result:
- other: The radioactive disintegrations per minute per animal and the stimulation index are given in Table 1.
Any other information on results incl. tables
Table 1 Individual Disintegrations per Minute and Stimulation Indices
Concentration (% w/w) in acetone/olive oil 4:1 |
Animal Number |
dpm/Animal† |
Mean dpm/Animal and Standard Deviation |
Stimulation Index‡ |
Result |
Vehicle |
1-1 |
1156.42 |
1315.45 ± 322.55 |
n/a |
n/a |
1-2 |
1269.53 |
||||
1-3 |
1091.83 |
||||
1-4 |
1178.36 |
||||
1-5 |
1881.10 |
||||
2.5 |
2-1 |
3278.14 |
3060.13 ± 1063.78 |
2.33 |
Negative |
2-2 |
3548.73 |
||||
2-3 |
4472.14 |
||||
2-4 |
2034.45 |
||||
2-5 |
1967.21 |
||||
5 |
3-1 |
2664.51 |
3155.04** ± 477.66 |
2.40 |
Negative |
3-2 |
3258.18 |
||||
3-3 |
3812.63 |
||||
3-4 |
2709.74 |
||||
3-5 |
3330.13 |
||||
10 |
4-1 |
4542.83 |
6305.34* ± 2422.81 |
4.79 |
Positive |
4-2 |
9364.26 |
||||
4-3 |
4870.27 |
||||
4-4 |
8489.79 |
||||
4-5 |
4259.55 |
dpm = Disintegrations per minute
†Total number of lymph nodes per animal is 2
‡Stimulation Index of 3.0 or greater indicates a positive result
n/a = not applicable
** Significantly different from control group p<0.01
* Significantly different from control group p<0.05
Clinical Observations and Mortality Data
There were no deaths. No signs of systemic toxicity were noted in the test or control animals during the test.
Bodyweight
Bodyweight changes of the test animals between Day 1 and Day 6 were comparable to those observed in the corresponding control group animals over the same period.
CALCULATION OF EC3 VALUE
EC3 = c + [[(3 - d) / (b - d)] x (a - c)]
a = 10
b = 4.79
c = 5
d = 2.40
EC3 = 6
The concentration of test item expected to cause a 3 fold increase in 3HTdR incorporation was calculated to be 6 %.
Applicant's summary and conclusion
- Interpretation of results:
- other: Sensitising
- Conclusions:
- The test item was considered to be a sensitiser under the conditions of the test.
- Executive summary:
The test item was considered to be a sensitiser under the conditions of the test. The test was conducted in accordance with OECD Guideline for the Testing of Chemicals No. 429 "Skin Sensitisation: Local Lymph Node Assay" (adopted 22 July 2010) and Method B.42 Skin Sensitisation (Local Lymph Node Assay) of Commission Regulation (EC) No. 440/2008.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.
Although ECHA is providing a lot of online material in your language, part of this page is only in English. More about ECHA’s multilingual practice.
Welcome to the ECHA website. This site is not fully supported in Internet Explorer 7 (and earlier versions). Please upgrade your Internet Explorer to a newer version.
the-echa-website-uses-cookies
find-out-more-on how-we-use-cookies