EC number: 226-798-2 | CAS number: 5470-11-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
Description of first aid measures
After inhalation: fresh air. Consult a physician.
After skin contact: wash off with plenty of water. Remove contaminated clothing. Consult a physician.
After eye contact: rinse out with plenty of water. Call in ophthalmologist.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.
Most important symptoms and effects, both acute and delayed
Allergic reactions, irritant effects, Dermatitis, Cyanosis.
The following applies to ammonium salts in general:
After swallowing: local irritation symptoms, nausea, vomiting, diarrhea.
Systemic effect - after the uptake of very large quantities: drop in blood pressure, collapse, CNS disorders, spasms, narcotic conditions, respiratory paralysis, haemolysis.
Indication of any immediate medical attention and special treatment needed
No information available.
Fire-fighting measures
Extinguishing media
Suitable extinguishing media: water, carbon dioxide, foam, dry powder.
Unsuitable extinguishing media: for this substance/mixture no limitations of extinguishing agents are given.
Special hazards arising from the substance or mixture
Combustible.
In the event of decomposition: danger of explosion.
Risk of dust explosion.
Development of hazardous combustion gases or vapours possible in the event of fire.
Fire may cause evolution of: hydrogen chloride gas, nitrogen oxides, nitrous gases.
Advice for firefighters
Special protective equipment for firefighters
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Further information
Suppress (knock down) gases/vapours/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system.
Accidental release measures
Personal precautions, protective equipment and emergency procedures
Advice for non-emergency personnel: avoid substance contact. Avoid inhalation of dusts. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Advice for emergency responders: Protective equipment see section “Exposure controls/personal protection”.
Environmental precautions
Do not empty into drains. Risk of explosion.
Methods and materials for containment and cleaning up
Cover drains. Collect, bind, and pump off spills.
Observe possible material restrictions (see sections “Handling and storage” and “Stability and reactivity”).
Take up dry. Dispose of properly. Clean up affected area. Avoid generation of dusts.
Reference to other sections
Indications about waste treatment see section “Disposal considerations”.
Handling and storage
Precautions for safe handling
Advice on safe handling: Observe label precautions. Work under hood. Do not inhale substance/mixture.
Hygiene measures: Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Conditions for safe storage, including any incompatibilities
Requirements for storage areas and containers: No metal containers.
Storage conditions: Tightly closed and away from sources of ignition and heat. Observe national regulations. Dry. Recommended storage temperature see product label.
Specific end use(s)
Apart from the use as a reagent for analysis, no other specific uses are stipulated.
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- UN 2923
Shipping information
- Proper shipping name and description:
- CORROSIVE SOLID, TOXIC, N.O.S. (HYDROXYLAMMONIUM CHLORIDE)
Special provisions / remarks
- Special provisions:
- Environmentally hazardous: yes
Special precautions for user: yes
Tunnel restriction code: E
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- Not relevant
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- UN 2923
Shipping information
- Proper shipping name and description:
- CORROSIVE SOLID, TOXIC, N.O.S. (HYDROXYLAMMONIUM CHLORIDE)
Special provisions / remarks
- Remarks:
- Environmentally hazardous: yes
Special precautions for user: yes
Transport in bulk according to Annex II of MARPOL 73/78 and IBC Code
Not relevant
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- UN 2923
Shipping information
- Proper shipping name and description:
- CORROSIVE SOLID, TOXIC, N.O.S. (HYDROXYLAMMONIUM CHLORIDE)
Special provisions / remarks
- Remarks:
- Environmentally hazardous: yes
Special precautions for user: no
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Control Parameters
Exposure Controls
Engineering measures: Technical measures and appropriate operations should be given priority over the use of personal protective equipment.
See section “Precautions for safe handling” in “Handling and Storage”.
Individual protection measures
Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled. The chemical resistance of the protective equipment should be enquired at the respective supplier.
Eye/face protection: Safety glasses
Hand protection
Full contact
Glove material: nitrile rubber
Glove thickness: 0.11 mm
Break through time: > 480 min
Splash contact
Glove material: nitrile rubber
Glove thickness: 0.11 mm
Break through time: > 480 min
The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril® L (full contact), KCL 741 Dermatril® L (splash contact).
The breakthrough times stated above were determined by KCL in laboratory tests according to EN374 with samples of the recommended glove types.
This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Other protective equipment: protective clothing
Respiratory protection:
Required when dusts are generated. Recommended filter type: Filter P 3 (according to DIN 3181) for solid and liquid particles of toxic and very toxic substances.
The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Environmental exposure controls
Do not empty into drains. Risk of explosion.
Stability and reactivity
Reactivity
Explosive
Mechanical sensitivity (friction).
Chemical stability
The product is chemically stable under standard ambient conditions (room temperature).
Possibility of hazardous reactions
Violent reactions possible with: alkaline substances
Possible formation of: hydroxylamine
Risk of explosion with: fire-promoting substances, oxidizing agents.
Conditions to avoid: heating (decomposition)
Incompatible materials: aluminum, copper, zinc, tin
Hazardous decomposition products: in the event of fire see section “Firefighting measures”
Disposal considerations
Waste treatment methods
See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have any further questions.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.